![Sturtevant Richmont Programmable Torque Verifier FM II Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/sturtevant-richmont/programmable-torque-verifier-fm-ii/programmable-torque-verifier-fm-ii_owners-manual_1387399025.webp)
Page 23
Chapter 4 - Programming the PTV-FM Generation II
Programming the PTV-FM is performed via the keyswitches on the faceplate of the unit. The
keyswitches work individually and in conjunction with each other to set the various components
of each parameter.
There are noticeable changes in programming the Generation II over the first generation of the
PTV-FM. The additional capabilities of this generation necessitated some, and suggestions from
the user community generated others. Please carefully read and follow the instructions in this
chapter until you are thoroughly familiar with programming under this regime.
Programming the Generation II follows some basic rules. They are:
1. The active parameter on the Parameter Selection Switch is the one programmed.
2. The first menu level consists of the elements of the selected parameter.
3. The UP keyswitch is the most efficient means of moving through the elements for each
parameter.
4. When the element of the parameter is displayed, the SET keyswitch is used to enter and exit
the submenu that programs the element (except for those that exit automatically upon com-
pletion).
5. The UP and DOWN keyswitches are used to move among the available options in the sub-
menu value selections, and the SET keyswitch is used to lock them in and either move to the
next value or return to the elements upon completion.
Elements of Each Parameter - Definitions
TBB . . . . . . . . . . . . . .Time Between Batches
TBC . . . . . . . . . . . . . .Time Between Clicks (in a batch)
TMAX . . . . . . . . . . . . .Time Maximum (maximum cycle/click duration for an acceptable click)
TMIN . . . . . . . . . . . . .Time Minimum (minimum cycle/click duration for an acceptable click)
BEEP . . . . . . . . . . . . .Beep (when the unit beeps to the operator)
RELAYS . . . . . . . . . . .Relay function (PLC)
CLEAR TOTAL . . . . . .Clears batch count
BATCH . . . . . . . . . . . .Batch count (number of fasteners for batch)
CLEAR WRENCHES .Clears memory of wrenches learned
CHANNEL SELECT . .Manual programming of the channel to be used.
MANUAL LEARN . . . .Learning the wrench on the manually-selected channel.
AUTO LEARN . . . . . . .Automatic detection of the channel and wrench for learning.
Prior to programming the unit for assembly line use it is necessary to have several pieces of
information at hand.
Содержание Programmable Torque Verifier FM II
Страница 4: ...Page 2...
Страница 6: ...Page 4 Photograph 2 Photograph 3...
Страница 20: ...Page 18...
Страница 36: ...Page 34...