Studer Innotec SA
RCC-02/-03
User manual
85
Level
User
ref.
Parameter
Unit
12
24
48
Mod.
value
Factory
Min
Max
Factory
Min
Max
Factory Min
Max
Expert
1171
Floating duration before reduced floating
days
1
0
31
1
0
31
1
0
31
Expert
1172
Reduced floating voltage
Vdc
13.2
9.5
18
26.4
19
36
52.8
37.9
72
Expert
1454
Periodic absorption phase
Expert
1173
Periodic absorption allowed
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1174
Periodic absorption voltage
Vdc
14.4
9.5
18
28.8
19
36
57.6
37.9
72
Expert
1175
Reduced floating duration before periodic
absorption
days
7
0
31
7
0
31
7
0
31
Expert
1176
Periodic absorption duration
hours
0.5
0
10
0.5
0
10
0.5
0
10
Expert
1186
INVERTER
Basic
1124
Inverter allowed
Yes/No
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1286
AC Output voltage
Vac
230
110
280
230
110
280
230
110
280
Expert
1548
AC voltage increase according to battery
voltage
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1560
Max AC voltage increase with battery voltage
Vac
10
5
15
10
5
15
10
5
15
Expert
1112
Inverter frequency
Hz
50
45
65
50
45
65
50
45
65
Expert
1536
Inverter frequency increase when battery full
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1549
Inverter frequency increase according to battery
voltage
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1546
Max frequency increase
Hz
4
0
10
4
0
10
4
0
10
Expert
1534
Speed of voltage or frequency change in
function of battery
0
-4
1
0
-4
1
0
-4
1
Expert
1420
Standby and turn on
Basic
1187
Standby level
%
10
0
100
10
0
100
10
0
100
Expert
1189
Time delay between standby pulses
sec
0.8
0.2
10
0.8
0.2
10
0.8
0.2
10
Expert
1188
Standby number of pulses
1
1
10
1
1
10
1
1
10
Expert
1599
Softstart duration
sec
0
0
1
0
0
1
0
0
1
Expert
1438
Solsafe presence Energy source at AC-Out
side
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1197
AC-IN AND TRANSFER
Expert
1128
Transfer relay allowed
Yes/No
Yes
-
-
Yes
-
-
Yes
-
-
Expert
1580
Delay before closing transfer relay
min
0
0
30
0
0
30
0
0
30
Basic
1126
Smart-Boost allowed
Yes/No
Yes
-
-
Yes
-
-
Yes
-
-
Inst.
1607
Limitation of the power Boost
%
100
0
100
100
0
100
100
0
100
Basic
1107
Maximum current of AC source (Input limit)
Aac
32
2
50
32
2
50
32
2
50
Expert
1471
Max input current modification
Expert
1566
Using a secondary value for the maximum
current of the AC source
No/Yes
No
-
-
No
-
-
No
-
-
Expert
1567
Second maximum current of the AC source
(Input limit)
Aac
16
2
50
16
2
50
16
2
50
Expert
1527
Decrease max input limit current with AC-In
voltage
No/Yes
No
-
-
No
-
-
No
-
-