Operating & Maintaining the Eden350V 3D Printer
6–66
DOC-03050 Rev. A
Test Descriptions
and
Troubleshooting
The
following
table
lists
the
name
of
each
test
in
the
Built
‐
in
Tests
suite,
together
with
its
description
and
a
possible
reason
for
its
failure.
If
you
need
assistance,
contact
your
Stratasys
service
provider.
Test Name
Description
Possible Reason for Failure
Sub
‐
System
Communication
Tests
communications
between
Eden
components.
•
Disconnected
communications
cable.
•
Faulty
cable.
FIFO
Non
‐
Interrupt/
FIFO
Interrupt
•
Tests
the
data
queue
in
the
DATA
PCI
card.
•
Tests
the
Windows
interrupt.
•
If
both
FIFO
tests
fail:
Faulty
DATA_PCI
card.
•
If
only
the
FIFO
Interrupt
test
fails:
Faulty
Windows
interrupt.
Encoder
Tests
the
encoder
ʹ
s
reliability
by
comparing
readings
from
multiple
runs
along
the
X
‐
axis.
Faulty
encoder.
System
Info
Compares
the
following
parameter
values
with
the
minimum
requirements.
•
physical
memory
•
available
memory
•
free
space
on
disk
•
monitor
resolution
Failure
of
RAM
memory
allocation
in
the
printer
computer.
RFID
Verifies
the
presence
of
RFID
tags
on
all
loaded
material
cartridges,
and
tests
them
by
writing
to
and
reading
from
each
one.
•
Faulty
RFID
reader.
•
Faulty
RFID
reader
power
supply.
•
Faulty
or
misaligned
RFID
tag.
•
High
level
of
electromagnetic
noise
around
the
RFID
tag.
System
Voltages
Checks
if
the
following
voltages
are
within
5%
of
the
required
voltage:
•
40V
to
the
heads
by
the
VPP
power
supply
•
12V
to
the
height
thermistors
by
the
VDD
power
supply
•
VPP
power
supply:
Faulty
head
drive(s).
•
VDD
power
supply:
Faulty
height
thermistor(s).
Block
Filling
Analyzes
the
thermistor
readings
when
the
block
is
full
and
when
it
is
empty.
Faulty
thermistor.
Interlock
Tests
the
interlock
in
the
printer
cover.
•
Failure
of
interlock
mechanism.
•
Faulty
latch.
•
Disconnected
cable.
Cabin
Temperature
Tests
the
temperature
level
in
the
build
‐
tray
area.
Faulty
temperature
sensor
(OHDB).
Head
EEPROM
Tests
the
read/write
capabilities
of
the
‐
head
driver
cards.
Faulty
‐
head
driver
card(s).
Head
Voltage
Checks
the
control
of
voltages
supplied
to
the
heads.
Faulty
‐
head
driver
card(s).
Head/Block
Heaters
Tests
the
heaters
in
the
heads
and
in
the
‐
block
body.
Faulty
heaters
or
thermistors.
UV
Lamps
Tests
each
UV
lamp
at
the
High
Quality
power
level.
Faulty
UV
lamp.
Faulty
UV
power
supply.
Disconnected
UV
cable.
Axes
Limit
Tests
the
hardware
and
software
limits
of
all
axes.
Faulty
hardware
sensors.
Wrong
Max
Position
parameter.
Parameter
Sanity
Check Compares
the
values
of
all
printer
parameters
(in
cfg
files)
to
the
required
values.
One
or
more
of
the
printer
parameters
is
not
within
the
required
range.
Details
appear
in
the
BIT
report.
Vacuum
Tests
the
vacuum
level
in
the
block.
•
Faulty
vacuum
sensor.
•
Vacuum
leakage.
•
Wrong
parameters.
Содержание Eden350V
Страница 1: ...User Guide English Eden350V 3D Printer System ...
Страница 2: ......
Страница 8: ......
Страница 20: ......
Страница 30: ......
Страница 31: ...DOC 03050 Rev A 4 1 Installing Objet Studio How to Install Objet Studio for the Eden 3D Printing System 2 ...
Страница 176: ......
Страница 182: ...Handling Printed Models 7 6 DOC 03050 Rev A ...