340 VM/HSC 6.0 System Programmer’s Guide
1st ed., 6/30/04 - 312579601
Media Type Prefix Characters
If discrepancies exist between the media type reported by the LMU (in the VAR) and the
VOLATTR information, the media type is prefixed by one of the following characters:
*
displayed if the VAR media type and VOLATTR information do not match. In this
case, the user should correct the erroneous VOLATTRs.
-
displayed if
both
of these conditions are true:
• a VOLATTR cannot be found for an ECART, ZCART, helical, or STK1
cartridge (anything other than a Standard cartridge), and
• the cartridge external media label has been verified by the LMU.
@
displayed if
both
of these conditions are true:
• a VOLATTR exists for an ECART, ZCART, helical, or STK1 cartridge
(anything other than a Standard cartridge), and
• the cartridge external media label has not been verified by the LMU.
Errant, Scratch, Selected Fields
A flag of ‘‘Y’’ (yes) under the Errant (Err), Scratch (Scr), or Selected (Sel) headings
indicates that the volume is currently in that status.
A volume in Errant (Err) status shows the volume’s home cell in the Cell Loc column.
Under the Selected heading, a flag of “Y” indicates that the volume is currently selected,
that is, being mounted, dismounted, ejected, or moved. A flag of “M” indicates that the
volume is currently mounted. The Selected column on the totals report includes both
selected and mounted volumes. The volume’s home cell appears in the Cell Loc column.
External Label Field
Under the heading External Label (Ext Lbl), ‘‘R’’ indicates that the volume has a readable
external label. A flag of ‘‘U’’ (unreadable) means that the cartridge has an external label
which the camera system is unable to read. ‘‘N’’ indicates that the cartridge has no
external label.
Cartridge Usability (CLN USE) Field
An ‘‘N’’ indicates a cartridge which is not usable, for example, a spent cleaning cartridge
that is not usable because it has exhausted its cleaning surface. An ‘‘M’’ means that a
cleaning cartridge has exceeded its maximum usage set by the VOLATTR MAXclean or
MNTD MAXclean value.
Volume Report
Содержание Host Software Component 6.0
Страница 1: ...Host Software Component VM Implementation System Programmer s Guide Release 6 0 312579601...
Страница 4: ...iv VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 24: ...xxiv VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 30: ...xxx VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 48: ...18 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 198: ...168 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 376: ...346 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 627: ...Appendix C Record Formats 597 1st ed 6 30 04 312579601 UVD994B5 CVAL Name Len Offset Value...
Страница 631: ...Appendix C Record Formats 601 1st ed 6 30 04 312579601 UVPTWSTD 03 UVPTYPE 000001 33 UVP9740 05 Name Len Offset Value...
Страница 632: ...602 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 683: ...Appendix F Batch Application Program Interface API 653 1st ed 6 30 04 312579601...
Страница 684: ...654 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 700: ...1st ed 6 30 04 312579601 670 VM HSC 6 0 System Programmer s Guide...
Страница 716: ...686 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 717: ......
Страница 718: ...Printed in U S A...