210 VM/HSC 6.0 System Programmer’s Guide
1st ed., 6/30/04 - 312579601
SLUADMIN (n.n.n) StorageTek Automated Cartridge System Utility PAGE 0001
TIME hh:mm:ss Control Card Image Listing DATE yyyy-mm-dd
AUDIT ACS(00) LSM(11)
SLUADMIN (n.n.n) StorageTek Automated Cartridge System Utility PAGE 0002
TIME hh:mm:ss Audit Utility DATE yyyy-mm-dd
-SLS0231I Audit phase 1 (Registration) completed
-
SLS2200I Warning: Volume MVC005 Media-type compare failed between VOLATTR and cartridge label
-SLS0232I Audit phase 2 (Volumes Check) completed
-
SLS0199I Volume CLN504 in cell 00:11:00:02:00 is in control data set at cell 00:11:00:00:00
SLS0199I Volume CLN505 in cell 00:11:00:02:05 is in control data set at cell 00:11:00:00:05
SLS0238I Audit scan for LSMid 00:11, panel 0 has completed
SLS0238I Audit scan for LSMid 00:11, panel 1 has completed
SLS0238I Audit scan for LSMid 00:11, panel 2 has completed
SLS0238I Audit scan for LSMid 00:11, panel 3 has completed
SLS0238I Audit scan for LSMid 00:11, panel 4 has completed
SLS0238I Audit scan for LSMid 00:11, panel 5 has completed
SLS0238I Audit scan for LSMid 00:11, panel 6 has completed
SLS0238I Audit scan for LSMid 00:11, panel 7 has completed
SLS0238I Audit scan for LSMid 00:11, panel 8 has completed
SLS0238I Audit scan for LSMid 00:11, panel 9 has completed
SLS0238I Audit scan for LSMid 00:11, panel 10 has completed
SLS0238I Audit scan for LSMid 00:11, panel 11 has completed
SLS0238I Audit scan for LSMid 00:11, panel 12 has completed
SLS0200I Volume Y20114 in cell 00:11:13:02:05 is not in control database
SLS0238I Audit scan for LSMid 00:11, panel 13 has completed
SLS0238I Audit scan for LSMid 00:11, panel 14 has completed
SLS0238I Audit scan for LSMid 00:11, panel 15 has completed
SLS0238I Audit scan for LSMid 00:11, panel 16 has completed
SLS0200I Volume Y20133 in cell 00:11:17:02:07 is not in control database
SLS0238I Audit scan for LSMid 00:11, panel 17 has completed
SLS0238I Audit scan for LSMid 00:11, panel 18 has completed
SLS0238I Audit scan for LSMid 00:11, panel 19 has completed
SLS0239I Audit scan for panels in LSMid 00:11 has terminated
-SLS0233I Audit phase 3 (Cell Scan) completed
SLS0213I Volume Y00133 not located by Audit
SLS0213I Volume Y00114 not located by Audit
-SLS0234I Audit phase 4 (Finish) completed
SLS0155I Condition code for utility function is 4
Figure 10. AUDIt Utility Sample Output
Audit
Содержание Host Software Component 6.0
Страница 1: ...Host Software Component VM Implementation System Programmer s Guide Release 6 0 312579601...
Страница 4: ...iv VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 24: ...xxiv VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 30: ...xxx VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 48: ...18 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 198: ...168 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 376: ...346 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 627: ...Appendix C Record Formats 597 1st ed 6 30 04 312579601 UVD994B5 CVAL Name Len Offset Value...
Страница 631: ...Appendix C Record Formats 601 1st ed 6 30 04 312579601 UVPTWSTD 03 UVPTYPE 000001 33 UVP9740 05 Name Len Offset Value...
Страница 632: ...602 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 683: ...Appendix F Batch Application Program Interface API 653 1st ed 6 30 04 312579601...
Страница 684: ...654 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 700: ...1st ed 6 30 04 312579601 670 VM HSC 6 0 System Programmer s Guide...
Страница 716: ...686 VM HSC 6 0 System Programmer s Guide 1st ed 6 30 04 312579601...
Страница 717: ......
Страница 718: ...Printed in U S A...