25
Overview hydraulic connections / acces
-
sories aluminium
Collector connections aluminium for collectros with aluminium pipe
Hydraulic connection set
clamping ring 90 °
Pressfitting M-Shape
Hydraulical connection T-piece
Pressfitting M-shape
Safety line
Please pay attention to the user instructions for the usage of collectors with full aluminium absorbers (aluminium sheet, alu-
minium pipe) mentioned below:
- All hydraulic connection fittings of the collector have to be made from aluminium or stainless steel.
- Hydraulic system components made from brass and copper must be mounted with a minimum distance of 2,5 m to the
collector.
- It is absolutely necessary that neither brass slivers nor copper slivers will be brought into the hyraulic system.
- The solar collector has to be a closed system. Additional air inlet from outside has to be avoided mandatorily. This is the
reason why open installations or those which are flushed directly with drinking water are not possible.
- The glycol used has to contain respective inhibitors. Additionally, the guidelines of the producer of glycol have to be observed
to assure a long-term protection of the installation.
- Recommended and tested heat transfer medium: Tyfocor ® L of the Tyforop GmbH
- At the solar station, pump or control system, it has to be highlighted that the collectors had been built with a full aluminium
absorber.
Notes Al/Al absorber
Collector connection hydraulic
Cap
Aluminium
Smart Lock System
Collector connection 22 mm
Aluminium
Smart Lock System
Содержание FKF 200
Страница 1: ...Assembly instructions Solar collectors FKF 200 240 270 Roof integrated installation...
Страница 43: ...43 Initial operation Schematic drawing of the system construction and piping scheme...
Страница 44: ...44 Initial operation Schematic drawing of the system construction and piping scheme...
Страница 45: ...45 Notes Initial operation...
Страница 46: ...46 Notes Initial operation...