21
Temperature sensor capturing
Cut the rubber tip for the
insertion of the temperature
sensor
The insertion depth of the sensor is limited to 4 cm. An additional
safeguard against a slipping out is recommended.
Due to the measuring point on the absorber, the sensor can be
installed at an arbitrarily chosen collector of the collector field.
The measurement deviation of the recorded temperature is
± 2 K compared with the medium temperature.
Assembly of the probe
Every collector is equipped with a sheath for the positioning of
a temperature sensor.
The position of the temperature sensor is located below the
upper left manifold outflow or to the left of the sticker with the
label „above“ at the outside of the frame profile. The sheath
for the insertion of the sensor is protected by a silicone cover
which has to be opened with a knife or a screw driver centred
before the insertion.