35
A
C
B
A
B
D
FKF 200/240/270 H
FKF
200/240/270 V
Assembly ridge sheet
Before installing the ridge sheets, the support sheets have to
be clicked into the groove of the collector profiles. Adjust the
position of appropriate components according to the measures
in the table above.
If there is no lath on the rest of the support sheets, install one
additionally.
Assembly dimensions support sheet & ridge sheet connection bottom part
Fix the support sheet with the appropriate screws before
mounting the ridge sheets.
Collektor
Measure
A
B
C
D
FKF 200/240/270 V
400 mm
800 mm
-
FKF 200 H
355 mm
710 mm
1.065 mm
1.420 mm
FKF 240 H
420 mm
840 mm
1.260 mm
1.680 mm
FKF 270 H
480 mm
960 mm
1.440 mm
1.920 mm