53
07/13424999918
GB
WPS
®
2 Window Protection System
X^J'X^J$<Y <^
<^ ` "<-
lation situation.
;;" <$ ^
]
be selected quite easily from the selection lists under the option “Security sensor technology” in the software. However,
parameters can also be set manually to make adjustments e.g. for a different switching strip. The operator of the WPS2
Y; "$ ]
Caution
#< Y"$ ";"$ ¥ ;
laid down in the Machinery Directive. Please follow the safety instructions provided in this manual.
The following parameters can be set:
Parameter [value range]
WPS2/A
WPS2/B
Max. window run time [0-255 seconds]
180 seconds
x
x
Reversing time [0-25.5 seconds]
3 seconds
x
x
Polarity reversal time [0-25.5 seconds]
0.5 seconds
x
x
Stop before reversal [0-25.5 seconds]
0.5 seconds
x
x
Symmetry correction [+/- 0-255 seconds]
5 seconds
x
x
Sensor technology time delay [0-255 seconds]
10 seconds
x
x
Motor disconnection active [Yes/No]
Yes
x
x
Fault message for fault in sensor monitoring [Yes/No]
No
x
-
Fault message for fault in switching strip monitoring [Yes/No]
No
x
x
Fault message for fault in hardware monitoring [Yes/No]
No
x
x
Fault message during emergency closing operation [Yes/No]
Yes
-
x
Supply from motor circuit [Yes/No]
Yes
x
-
Emergency close input active? [Yes/No]
No
-
x
SHE input active? [Yes/No]
No
-
x
Switching strip input active? [Yes/No]
No
x
x
Active infrared sensor input active? [Yes/No]
No
x
x
Radar sensor input active? [Yes/No]
No
x
-
Passive infrared sensor input active? [Yes/No]
No
-
x
Signal transducer active? [Yes/No]
No
x
x
Switching strip signal disconnection delayed? [Yes/No]
No
x
x
Active infrared signal disconnection delayed? [Yes/No]
No
x
-
Radar contact 1 signal disconnection delayed? [Yes/No]
No
x
-
Radar contact 2 signal disconnection delayed? [Yes/No]
No
x
-
Radar sensor has frequency output? [Yes/No]
No
x
-
Passive IR sensor signal disconnection delayed? [Yes/No]
No
x
x
Test output [Passive/active]
Passiv
x
-
Test input [Low passive/high active]
Low Aktiv
x
-