Installation and Service Manual
29
SK 2055 / 2070 / 2090
SK 2070 - SK 2090
Pouring a new foundation.
If the conditions specified above have not been met, a new foundation needs to
be poured in accordance with the following specifications:
Volume of the concrete:
• SK2055: 5 x 2,5 x 0,15 = 1.9 m3
• SK2070: 5 x 2,5 x 0,175 = 2.2 m3
• SK2090: 5 x 2,5 x 0,22 = 2.75 m3
Reinforcement:
• At least 2 mats of 150x150x8, quality FEB500
Max. resulting ground pressure:
• 0.1 kg/cm2