7
INSTALLATION
VENUS COMFORT 2032 / 2032 E
5) Connect the other electronic unit connector to
the power supply (battery or transformer).
6) Before you assemble the wall cover panel,
consider to use the provided adjusting screw in order
to optimize the operation of the mechanical button.
If needed, assemble the adjusting screw to the
mechanical button at the internal side of the panel
and adjust it to the desired distance.
7) If your model is operated by battery, insert the
battery into the battery box.
8) Assemble the wall cover panel to the cover seat
and tighten it with the bottom screw.
9) If your model is operated by transformer, plug the transformer to the main
electricity supply.
Important:
To prevent the sensor from entering into adjusting
mode, do not step or put your hand within the sensor range for
5 seconds after the connection of the power supply.
10) Remove the protective sticker covering the sensor and
move away from the sensor range
.
11) Move away from the sensor to activate the flush valve. The
valve will flush a few seconds after your departure.
12) If needed adjust the flow capacity by turning the regulating
valve.