14
SETTINGS ADJUSTMENT
DELAY IN TIME: This function c
hanges the time interval in which
the sensor will activate the system if the user is detected for the
preset amount of seconds.
If required, the delay in time can be modified as follows:
Press the IN button. Wait until a quick flashing of the red light of
the sensor eye is perceived. Then, press + to increase the delay
in time and – to reduce it.
FULL FLOW TIME:
This function determines the water flushing time
once the user leaves the W.C. Press the two waves button. Wait
until a quick flashing of the red light of the sensor eye is perceived.
Then, press + to increase the flow time and – to reduce it.
Adjusting other settings with the remote control
DETECTION RANGE: Only if necessary
, use the remote control to
adjust the sensor range as follows:
Press the RANGE button. Wait until a quick flashing of the red light
of the sensor eye is perceived. At this stage, you can increase or
decrease the sensor range by pressing the (+) or the (-) buttons,
every push will increase or decrease one level.
Note:
Once you have changed the detection range with the remote control,
this distance will be remembered by the sensor, even if the power source is
disconnected.