ZP-MEC3-BX-01A 

SHR 150/200 Manual 

RD: MAY, 2004 

RL:1 

KH

 

VALVE ASSEMBLY 

FIGURE   1 

1.      Remove valve and heater from carton.   
         Remove the three screws from each venturi 
         collector bell located on one end of the  
        heater. 
 
2.      Slide valve onto collector bells and insert 
         two vertical screws.  Then install remaining 
         four screws. 
 
3.      To avoid possible damage to wiring connec-
         tion, it may be advantageous to hang heater 

        before connecting wires.  Connect two gray  
        wires to the flame sensors located by the 
        electrodes.  Connect the two spark-plug 
        type high tension leads to the Electronic 
        Ignition Control.  If a thermostat is used, 
        separate the two red wires that are twisted 
        together and connect the thermostat 
        between them.  If a thermostat is not used, 
        connect the red wires to the positive side 
        of the power source and the single blue  
        wire to the negative via a switch. 

HEATER INSTALLATION 

Installation of Sterling Gas Fired Infra-Red 
Heaters should conform to all Sterling Heating 
Installation Design Procedures including ventila-
tion.  All local and national codes requirements, 
or in the absence of local codes, the National 
Electrical Code (NFPA No. 70) and the National 
Fuel Gas Code (ANSI A223.1 – latest edition) 
 
 

in the U.S.A. or in Canada CSA B149.1-00 shall 
be followed.  ANSI  Z223.1, is available from 
the International Gas Association 8501 East 
Pleasant Valley Road, Cleveland OH  44131, 
and all NFPA codes are available from National 
Fire Prevention Association, Batterymarch Park, 
Quincy, NA  02269. 

Содержание SHR150

Страница 1: ...ra tion service or maintenance can cause property damage injury or death Read the instructions thoroughly before install ing or servicing this equipment FOR YOUR SAFETY DO NOT store or use gasoline or...

Страница 2: ......

Страница 3: ...the heater Failure to do so could cause property damage bodily injury or death Rigid mounting should be used in the above application DO NOT hang heater on gas lines water lines conduit etc Hang only...

Страница 4: ...13 Please call your local heating parts supplier and or gas company for orifices in your area IMPORTANT WARNING Do Not alter the installed orifice in any manner Improper alteration could result in Ca...

Страница 5: ...are twisted together and connect the thermostat between them If a thermostat is not used connect the red wires to the positive side of the power source and the single blue wire to the negative via a...

Страница 6: ...s by wearing personal protective equipment such as gloves and safety glasses to avoid being injured by sharp metal edges in or around the heater and while cutting or drilling holes Failure to follow t...

Страница 7: ...e largest aircraft to be housed in the hangar 2 A minimum clearance of 8 feet must be maintained from the bottom of the heater in other sections of the aircraft hangars such as offices and shops 3 The...

Страница 8: ...xis Improper angle mounting can result in overheat ing of controls and combustible materials The hangers support the infra red heater and the reflectors Chain with a working load of at least 200 lbs i...

Страница 9: ...pipe joint union is required at the gas inlet connection to the control valve on the heater All components upstream of the control valve are field sup plied by the installer See Figure 4 2 If permitte...

Страница 10: ...d pressure with a water manometer to verify proper operation of the heater A pressure regulator is an integral part of the automatic valve on all models for both Natural and LP Gas This pressure regul...

Страница 11: ...trol is powered by a 24 VAC transformer and activated when the temperature control requests for heat When the control is activated by the temperature control s request for heat control performs a safe...

Страница 12: ...OR 24 VAC ACROSS VALVES AND VALVES TERMI NALS ON CONTROL IF NO VOLTAGE REPLACE CONTROL SPARK IGNITERS MAY BE OUT OF POSITION CHECK ELEC TRICAL CONNECTIONS BETWEEN CONTROL GAS VALVES IF OKAY REPLACE GA...

Страница 13: ...ide of the ceramic This can be very easily removed by dusting the ceramic face and the air inlet with a blast of low pressure air a maximum of 20 psi Occasionally pilots or the burners refuse to funct...

Страница 14: ...448 G1 12 Gasket Fiberfraux 49929 G1 49929 G1 49229 G1 49229 G1 13 Ceramic Tile 52138 G2 52138 G2 52138 G2 52138 G2 14 Central Tile Divider 51878 G1 51878 G1 51878 G1 51878 G1 15 Tile Retainer 51295 G...

Страница 15: ...DARD ORIFICE DMS FOR USE AT ALTITUDES ABOVE FEET 2000 3000 4000 5000 6000 7000 8000 SHR150L 27 28 28 29 29 29 30 30 PART NO 49955 G18 49955 42 49955 42 49955 G11 49955 G11 49955 G11 49955 G1 49955 G1...

Страница 16: ...r 5 All service and warranty claims must have the product model and serial number on the Returned Material Tag Under no circumstances should anyone ex cept a professional gas heating equipment service...

Страница 17: ...perature or open flame excessive thermal shock physical damage impact or abrasion alterna tions by unauthorized service operation contrary to Sterling s instructions or if the serial number has been...

Отзывы: