TROUBLE SHOOTING GUIDE 

SERVICE HINTS AND MAINTENANCE 

CAUSE AND CORRECTIONS 

TURN THERMOSTAT TO CALL FOR HEAT  

24 VOLTS AT CONTROL TRANSFORMER 

24 VOLT AT CONTROL 

24 VOLTS OUT CONTROL 

24 VOLTS AT GAS CONTROL 

SPARK ACROSS IGNITER 
OR IGNITER/SENSOR GAP 

MAKE SURE THE MANUAL 
LEVER ON THE VALVES 
ARE OPEN AND THAT 
THERE IS GAS GOING TO 
THE VALVES. 

MAIN BURNERS LIGHT 

SPARKS STOPS 
WHEN BURNERS 
ARE  LIT. 

SYSTEM RUNS UNTIL 
CALL FOR HEAT ENDS 

CHECK FOR LINE VOLTAGE POWER SUPPLY 

CHECK 24V WIRING FROM IGNITION CON-
TROL TO GAS VALVE 

PULL IGNITION LEAD AND CHECK SPARK AT 
IGNITION STUD. 
CAUTION:  HIGH VOLTAGE 
SPARK OKAY?? 

CHECK 24V WIRING FROM TRANSFORMER 
TO IGNITION CONTROL 

REPLACE CONTROL 

REPLACE TRANSFORMER 

CHECK IGNITION CABLE, GROUND WIRE, CERAMIC INSULA-
TOR AND CAP, AND CORRECT.  CHECK BOOT OF THE IGNI-
TION CABLE FOR SIGNS OF MELTING OR BUCKLING.  TAKE 
PROTECTIVE ACTION TO SHIELD CABLE & BOOT FROM EX-
CESSIVE TEMPERATURES. 

CHECK FOR 24 VAC ACROSS VALVES AND VALVES TERMI-
NALS ON CONTROL IF NO VOLTAGE, REPLACE CONTROL. 
SPARK IGNITERS MAY BE OUT OF POSITION.  CHECK ELEC-
TRICAL CONNECTIONS BETWEEN CONTROL & GAS VALVES IF 
OKAY, REPLACE GAS VALVES OPERATOR. 

YES 

NO 

YES 

NO 

YES 

YES 

YES 

YES 

NO 

YES 

NO 

NO 

NO 

NO 

NOTE: IF CONTROL GOES INTO LOCKOUT, RESET SYSTEM BY 
INTERRUPTING POWER SOURCE. 
CHECK CONTINUITY OR SENSOR CABLE AND GROUND WIRE.  
CHECK THAT BURNER FLAME COVERS ALL ELECTRODES. 
CHECK GROUND CONTINUITY. IF CHECKS ARE OKAY, RE-
PLACE CONTROL MODULE. 

NOTE: IF CONTROL GOES INTO LOCKOUT, RESET SYSTEM BY 
INTERRUPTING POWER SOURCE. 
CHECK CONTINUITY OR SENSOR CABLE AND GROUND WIRE.  
NOTE: IF GROUND IS POOR OR ERRATIC, SHUTDOWN MAY 
OCCUR OCCASIONALLY EVEN THOUGH OPERATIONS IS NOR-
MAL AT THE TIME OF CHECKOUT. 
IF CHECKS ARE OKAY, REPLACE CONTROL MODULE. 

YES 

YES 

NO 

YES 

NO 

CHECK FOR PROPER TEMPERATURE CONTROLLER OPERA-
TION. REMOVE VALVE LEAD AT CONTROL IF VALVE CLOSES, 
RECHECK TEMPERATURE CONTROLLER AND WIRING; IF NOT, 
REPLACE GAS VALVE OPERATOR. 

CALL FOR HEAT ENDS; 
SYSTEM SHUTS OFF 

YES 

TROUBLE SHOOTING ENDS 

YES 

NO 

REPEAT PROCEDURE UNTIL TROUBLE FREE OPERATIONS IS OBTAINED. 

Содержание SHR150

Страница 1: ...ra tion service or maintenance can cause property damage injury or death Read the instructions thoroughly before install ing or servicing this equipment FOR YOUR SAFETY DO NOT store or use gasoline or...

Страница 2: ......

Страница 3: ...the heater Failure to do so could cause property damage bodily injury or death Rigid mounting should be used in the above application DO NOT hang heater on gas lines water lines conduit etc Hang only...

Страница 4: ...13 Please call your local heating parts supplier and or gas company for orifices in your area IMPORTANT WARNING Do Not alter the installed orifice in any manner Improper alteration could result in Ca...

Страница 5: ...are twisted together and connect the thermostat between them If a thermostat is not used connect the red wires to the positive side of the power source and the single blue wire to the negative via a...

Страница 6: ...s by wearing personal protective equipment such as gloves and safety glasses to avoid being injured by sharp metal edges in or around the heater and while cutting or drilling holes Failure to follow t...

Страница 7: ...e largest aircraft to be housed in the hangar 2 A minimum clearance of 8 feet must be maintained from the bottom of the heater in other sections of the aircraft hangars such as offices and shops 3 The...

Страница 8: ...xis Improper angle mounting can result in overheat ing of controls and combustible materials The hangers support the infra red heater and the reflectors Chain with a working load of at least 200 lbs i...

Страница 9: ...pipe joint union is required at the gas inlet connection to the control valve on the heater All components upstream of the control valve are field sup plied by the installer See Figure 4 2 If permitte...

Страница 10: ...d pressure with a water manometer to verify proper operation of the heater A pressure regulator is an integral part of the automatic valve on all models for both Natural and LP Gas This pressure regul...

Страница 11: ...trol is powered by a 24 VAC transformer and activated when the temperature control requests for heat When the control is activated by the temperature control s request for heat control performs a safe...

Страница 12: ...OR 24 VAC ACROSS VALVES AND VALVES TERMI NALS ON CONTROL IF NO VOLTAGE REPLACE CONTROL SPARK IGNITERS MAY BE OUT OF POSITION CHECK ELEC TRICAL CONNECTIONS BETWEEN CONTROL GAS VALVES IF OKAY REPLACE GA...

Страница 13: ...ide of the ceramic This can be very easily removed by dusting the ceramic face and the air inlet with a blast of low pressure air a maximum of 20 psi Occasionally pilots or the burners refuse to funct...

Страница 14: ...448 G1 12 Gasket Fiberfraux 49929 G1 49929 G1 49229 G1 49229 G1 13 Ceramic Tile 52138 G2 52138 G2 52138 G2 52138 G2 14 Central Tile Divider 51878 G1 51878 G1 51878 G1 51878 G1 15 Tile Retainer 51295 G...

Страница 15: ...DARD ORIFICE DMS FOR USE AT ALTITUDES ABOVE FEET 2000 3000 4000 5000 6000 7000 8000 SHR150L 27 28 28 29 29 29 30 30 PART NO 49955 G18 49955 42 49955 42 49955 G11 49955 G11 49955 G11 49955 G1 49955 G1...

Страница 16: ...r 5 All service and warranty claims must have the product model and serial number on the Returned Material Tag Under no circumstances should anyone ex cept a professional gas heating equipment service...

Страница 17: ...perature or open flame excessive thermal shock physical damage impact or abrasion alterna tions by unauthorized service operation contrary to Sterling s instructions or if the serial number has been...

Отзывы: