ZP-MEC3-BX-01A
SHR 150/200 Manual
RD: MAY, 2004
RL:1
KH
TABLE OF CONTENTS
Warnings 1
Ratings 2
Unpacking 2
Heater Installation 3
Choosing Heater Location 4
Minimum Clearance 4
General Mounting Instruction 6
Angle Mounting 7
Ventilation Requirements 7
Piping 7
Testing for Leaks 8
Manifold Pressure Checking 8
Spark Ignition System 9
Service Person’s Trouble Shooting Guide 10
Replacement Parts
Diagram 11
List 12
Main Burner Orifice 13
Procedure for Service warranty Claim 14
Customer’s record 14
Warranty Back Cover
WARNING
DO NOT Install or service this heater yourself. Call a
Professional gas heater equipment service person.
●
DO NOT place flammable material on or
near the heater.
●
When used with a thermostat, heater may
start at any time.
●
Use only in well ventilated areas. DO NOT
install in an area where the heater could be
isolated.
●
DO NOT obstruct the flow of combustion
and ventilation air.
●
The installation must conform with local
codes or, in the absence of local codes, with
the National Fuel Gas Code, ANSI Z221.1*
in U.S.A. or in Canada CAN 1.2.16M81.
●
DO NOT hang the heater with chains in
applications where repetitive swinging
motion of the heater may fatique the gas
connections to the heater or damage the
heater. Failure to do so could cause
property damage, bodily injury or death.
Rigid mounting should be used in the above
application.
●
DO NOT hang heater on gas lines, water
lines conduit, etc. Hang only on structural
member (s) which could sufficiently support
the heater without impairing or endangering
other functions of the structural member (s).
●
If heater is installed at altitudes 2,000 feet
or more above sea level the orifice must be
changed according to the chart on page 13.
●
DO NOT use this heater if any part has
been under water. Immediately call a
professional gas heating equipment service
person to inspect the heater and to replace
any part which has been under water.
●
Any changes to this heater or its controls
can be dangerous. Any additions, changes
or conversions required in order for this
heater to satisfactory meet the application
needs must be made by a profesiional gas
heating equipment service person using
factory specified and approved parts.
●
Any safety screen, guard or part removed
for installation or service must be replaced
prior to operating the heater to avoid
property damage, bodily injury or death.
*
ANSI Z223.1 (latest edition) is available from American Gas
Association, 8501 East Pleasant Valley Rd., Cleveland OH
44131 (216-524-4990), and all NFPA codes are available
from National Fire Prevention Association, Batterymarch Park
Quincy, MA 02269 (617-770-3000) or check your local library.
1