WHAT IS COVERED 

 

Sterling warrants that this product is free from 
defects in material or workmanship under normal 
use and service subject to the terms of this docu-
ment. 
 

ONE YEAR WARRANTY 

 

Sterling’s sole obligation under this warranty shall 
be limited to furnishing replacement parts, for 12 
months from date of initial installation of the 
heater, but not to exceed 18 months from the 
date of shipment by Sterling of the heater, for any 
parts which Sterling’s examination shall disclose 
to its satisfaction to be defective.  Defective parts 
are to be returned to Sterling, with transportation 
charges prepaid. 
 

ADDITIONAL LIMITED WARRANTY 

 
In addition to the above mentioned First-year 
Warranty, Sterling warrants to the original pur-
chaser of a C.S.A. Certified Infra-Red Heater the 
following. That at any time during the nine (9) 
year period following the expiration of the first-
year Warranty, at the discretion of Sterling will 
repair or replace to original or equivalent design, 
the Effect-Tile Burner exclusive of control, which 
proves to be inoperable due to defects in material 
or factory workmanship to the satisfaction of 
Sterling. Sterling’s sole obligation under this Ad-
ditional Limited Warranty shall be limited to fur-
nishing Effect Tile Burners only. 

 

WHAT IS NOT COVERED 

 
Sterling will not be responsible for labor charges 
for analysis or a defective condition in the heater 
or for installation of replacement part.  The War-
ranties provided herein will not apply if the input 
of the heater exceeds the rated input, as indi-
cated on the name plate, by more than 5%, or if 
the heater in the judgment of Sterling has been 
subjected to misuse, negligence, accident, con-
taminated and/or corrosive atmospheres, condi 

 
 
 
tions which create a contaminated and/or corro 
sive atmosphere in the presence of high tem-
perature or open flame, excessive thermal shock, 
physical damage, impact, or abrasion, alterna-
tions by unauthorized service, operation contrary 
to Sterling’s instructions or if the serial number 
has been altered, defaced, or removed.  Sterling 
shall not be liable for any default or delay in per-
formance by it of these warranties caused by any 
contingency beyond its control, including war, 
government restrictions or restraints, strikes, fire, 
flood, or short or reduced supply of raw material, 
or parts.  Written permission is required for the 
return of any parts of equipment and such return 
must be made on the basis of transportation 
charges prepaid.  Shipments may be refused 
unless prior permission is obtained, and returned 
prepaid.  This Warranty applies only within the 50 
United States of America. 
 

LIMITATIONS AND EXCLUSIONS

 

 
This document contains all warranties made by 
Sterling and may not be varied, altered or ex-
tended by any person.  There are no promises, 
or agreements extending from Sterling other than 
the statements contained herein.  THIS WAR-
RANTY IS IN LIEU OF ALL WARRANTIES EX-
PRESS OR IMPLIED, TO THE EXTENT AU-
THORIZED BY THE LAWS OF THE STATE OF 
SALE, INCLUDING SPECIFICALLY THE WAR-
RANTIES OF MERCHANTIBILITY OR FITNESS 
FOR A PARTICULAR PURPOSE. 
 
        It is understood and agreed that Sterling’s 
obligation hereunder is limited to repairing or re-
placing parts determined to be defective as 
stated above. 
 
        In no event shall Sterling be responsible for 
any alleged personal injuries or other special inci-
dental or consequential damages. 
 

 GAS-FIRED INFRA-RED HEATER LIMITED WARRANTY 

Some states do not allow certain warranty exclu-
sions or limitations on how long a warranty lasts 
or the exclusions or limitations of incidental or 
consequential damages.  In such states, the 
above limitations or exclusions may not apply to 
you and are not intended to do so where prohib-
ited by law. This warranty gives you specific legal  
rights. You may also have other rights which vary 
from state to state. 

 

STERLING HVAC EQUIPMENT 

260 NORTH ELM STREET 

WESTFIELD, MA  01085 

Содержание SHR150

Страница 1: ...ra tion service or maintenance can cause property damage injury or death Read the instructions thoroughly before install ing or servicing this equipment FOR YOUR SAFETY DO NOT store or use gasoline or...

Страница 2: ......

Страница 3: ...the heater Failure to do so could cause property damage bodily injury or death Rigid mounting should be used in the above application DO NOT hang heater on gas lines water lines conduit etc Hang only...

Страница 4: ...13 Please call your local heating parts supplier and or gas company for orifices in your area IMPORTANT WARNING Do Not alter the installed orifice in any manner Improper alteration could result in Ca...

Страница 5: ...are twisted together and connect the thermostat between them If a thermostat is not used connect the red wires to the positive side of the power source and the single blue wire to the negative via a...

Страница 6: ...s by wearing personal protective equipment such as gloves and safety glasses to avoid being injured by sharp metal edges in or around the heater and while cutting or drilling holes Failure to follow t...

Страница 7: ...e largest aircraft to be housed in the hangar 2 A minimum clearance of 8 feet must be maintained from the bottom of the heater in other sections of the aircraft hangars such as offices and shops 3 The...

Страница 8: ...xis Improper angle mounting can result in overheat ing of controls and combustible materials The hangers support the infra red heater and the reflectors Chain with a working load of at least 200 lbs i...

Страница 9: ...pipe joint union is required at the gas inlet connection to the control valve on the heater All components upstream of the control valve are field sup plied by the installer See Figure 4 2 If permitte...

Страница 10: ...d pressure with a water manometer to verify proper operation of the heater A pressure regulator is an integral part of the automatic valve on all models for both Natural and LP Gas This pressure regul...

Страница 11: ...trol is powered by a 24 VAC transformer and activated when the temperature control requests for heat When the control is activated by the temperature control s request for heat control performs a safe...

Страница 12: ...OR 24 VAC ACROSS VALVES AND VALVES TERMI NALS ON CONTROL IF NO VOLTAGE REPLACE CONTROL SPARK IGNITERS MAY BE OUT OF POSITION CHECK ELEC TRICAL CONNECTIONS BETWEEN CONTROL GAS VALVES IF OKAY REPLACE GA...

Страница 13: ...ide of the ceramic This can be very easily removed by dusting the ceramic face and the air inlet with a blast of low pressure air a maximum of 20 psi Occasionally pilots or the burners refuse to funct...

Страница 14: ...448 G1 12 Gasket Fiberfraux 49929 G1 49929 G1 49229 G1 49229 G1 13 Ceramic Tile 52138 G2 52138 G2 52138 G2 52138 G2 14 Central Tile Divider 51878 G1 51878 G1 51878 G1 51878 G1 15 Tile Retainer 51295 G...

Страница 15: ...DARD ORIFICE DMS FOR USE AT ALTITUDES ABOVE FEET 2000 3000 4000 5000 6000 7000 8000 SHR150L 27 28 28 29 29 29 30 30 PART NO 49955 G18 49955 42 49955 42 49955 G11 49955 G11 49955 G11 49955 G1 49955 G1...

Страница 16: ...r 5 All service and warranty claims must have the product model and serial number on the Returned Material Tag Under no circumstances should anyone ex cept a professional gas heating equipment service...

Страница 17: ...perature or open flame excessive thermal shock physical damage impact or abrasion alterna tions by unauthorized service operation contrary to Sterling s instructions or if the serial number has been...

Отзывы: