SHR
150,000 – BTUH
200,000 – BTUH
N – Natural
L – Liquid
Petroleum/
Propane
ALTITUDE ORIFICE CHANGES
When the heater is installed at altitudes exceed-
ing 2,000 feel above sea level, the input must be
reduced by 4 percent for each 1,000 feet above
sea level.
Example: SHR150 installed at 4,000 feet
altitude;
Normal Input Rate 150,000 BTUH
Less 16% for 4,000 feet
above sea level 24,000 BTUH
Reduced input for 4,000
feet altitude 126,000 BTUH
For correct size orifice, refer to altitude orifice
conversion chart on page 13. Please call your
local heating parts supplier and/or gas company
for orifices in your area.
IMPORTANT
WARNING
Do Not alter the installed orifice in any manner.
Improper alteration could result in Carbon
Monoxide poisoning and possible death. If the
orifice must be changed or cleaned contact a
professional gas heating equipment service
person.
CHECKING FOR DAMAGE OR SHORTAGES
1. Unpack the heater from its carton and
examine the contents for damage or missing
parts.
2. If any parts are damaged at the time of deliv-
ery, notification should be made on the Bill of
Lading from the transportation
company.
3. Concealed damage must be filed within
fifteen (15) days with the carrier.
4. Claims for shortage must be filed with the
distributor within five (5) days.