15
"side" condition
potential source of error
LCD display gone out
no power supply, maybe safety fuse
or current feed defective
S
manual switch-off of solar
ubmenu "MAN.OPERA
circulation
TION"
(manual operation) selected
. storing
)
pump
Storing temp. T2 near or above storing temp.
limitation has switched off the configurated max
temp.pump
Indication of an error
sensor conductor or sensor defective
(e. g. short circuit T1 and/or T2, or cut off
(Note: only output R1 (solar circuit pump)
interruption T1 and/or
switches off in the case of T1 or T2
T2)
sensor
defect.
Output
R2
remains
unaffected
Collector sensor shows wrong temperature
"side" condition
potential source of error
" a wrong
n operation
Collector sensor T1 shows
In the submenu "FUNCTIONS
a value of 180°C or a negative value temp.
sensor has been selected
alorimeter registrates no or wrong heat quantity despite of solar pump i
C
Potential source of error:
nt temp. registration) or temp.
•
temp. sensor T4 (forward moveme
sensor T5 (backward movement temp. registration) or external volume
flow
dispenser
(controller
input point Imp.) have not or incorrectly been
connected.
•
function calorimetry has not been selected
forward and backwa
nsors have been exchanged
ht have been
L
•
rd movement temp. se
rong input of wrong impulse valency of vo
•
w
lume flow dispenser
•
wrong configuration of proportion of mixture water /solar liquids
•
volume indicator shows no discharge
he wrong direction
- volume indicator installed in t
- obstruction of the volume indicator filter that mig
installed
-
air
within
the
solar
circuit
•
Usage of another solar liquid than Tyfocor
Indication of error in the LCD display
Short circuits and interruptions of each single temp. sensor are only indicated when the corresponding sensors are
y.
really in use on the basis of the selected funtion.
The controller automatically recognizes the below-described errors and indicates them after 10 sec on its LCD displa
Only after confirming by pressing a button does the controller start working regularly again. If a malfunction is not
eliminated despite indication and confirmed the LCD display indicates again error. When there are several errors the
one with the "lowest impact" (e. g. first T1, then T2 etc.) is indicated.
Note:
If the controller recognizes an error the output of the controller switches off due to safety reasons.
Display indicates the
following
Significance
Short circuit T1
short circuit of sensor conductor T1 for the registration of the collector temperature
Interruption T1
Cut-off of sensor conductor T1 for the registration of the collector temperature
Short circuit T2
short circuit of sensor conductor T2 for the registration of the „storage tank temp. bottom“
Interruption T2
Cut-off of sensor conductor T2 for the registration of the „storage tank temp. bottom“
Short circuit T3
short circuit of sensor conductor T3 for the registration of the „storage tank temp. top“
Interruption T3
Cut-off of sensor conductor T3 for the registration of the „storage tank temp. top“
stt: No °C
temp. sensor T3 not existing (T3 is normally only needed for the indication of storing high
temp. and so exclusively necessary within the function heating system)
Display indicates the
following
Significance