13
5.3 Connecting the controller
First of all leave open the wire inputs for the power supply
connection and the connecting wires of the sensors and the pump
in the casing box. For this purpose there are material draws to be
cut out (Illustration 4, Pos.
c
). Each wire input needs two vertical
cuts into the wall of the plastic case. For the cutting you can use
cable stripping knife or an electronic side cutter. The cutting d
should be 2 mm min. from the plastic case ground. Afterwa
the plastic clip can be taken out by moving it back and forth.
epth
rds
ustration 4: material gap for wire entrance
The connecting activities as described here are only possible when the terminal box cover plate of the
on
,
connecting wires to the prescribed
ill
controller is open. For this purpose clear the power supply net. Stick to all valid regulations for working
cleared power supply net. Only connect to the power supply net when controller case is closed. Moreover
the user has to take care of the fact that the IP protection is not damaged.
Connect net and pump
a
draws (Illustration 6, Pos
c
to
). Each draw can only be
furnished with one connecting wire (up to 2.5 mm2). For
fine-strand wires please use end sleeves for strands. Outsid
the controller the wires must be strain-relieved.
Storing and collector sensor are to be connected
e
to the
prescribed draws (illustration 6, Pos
to
). In this
context the polarity does not play a role. Outside the
controller the wires must be strain-relieved.
Attention:
Only use original sensors specified for this
If the pumps or the reversing valves are planed or prescribed for being connected to a grounded
he
ear
ustration 6: controller clamps
onnections:
controller (sensors KTY81-210 or PT1000).
illustration 5: Connection clamp
conductor this MUST also be connected. For this purpose there are draws. Please make sure that t
ing contact is led to the controller also on the power supply side.
th
ill
C
8
9
10
4
1
2
3
5
6
7
11 12
clamp-number
w
ir
e
strap o
u
tput R
2
: rem
o
ve
w
ire
stra
p
fo
r power fr
ee
ou
tput
R
2
pe
rm
anen
t pha
se
230 V
for
3-
w
ay
r
evers
ing val
v
es wit
h
relay
n
o-vol
tage cond
uc
tor
R2
swi
tch
o
u
tput
R2
su
pply v
o
lt
age
230 V
gro
u
n
ded c
ondu
c
tor
swi
tch o
utp
ut R2
supply voltage
extra low potential
T1
T2
T3
T4
T5
Imp.
pulse input
calorimeter
13 14 15 16 17 18 19 20 21 22 23 24
24
23
24
23
gro
und
ed con
ducto
r
solar ci
rculatio
n pu
m
p
solar c
irculat
ion
pum
p
fu
s
e
:
s
w
itch
out
put
R2
fuse:
so
la
r circ
ulation
pum
p
sensor
c
o
lle
c
tor
s
e
n
s
or
s
to
rag
e
t
a
nk
b
e
low
sensor
storag
e ta
nk
top
senso
r calor
ime
ter
solar f
o
rward
or sen
s
or
circ
ulation
se
n
s
or ca
lorimet
e
r sola
r re
turn