EN
22
Program selection Name
Option Meaning
11
Maximum
duration of the
equalizing charge
in case the
voltage of the
equalizing charge
is not reached
permanently
300
Can be set from 5 min to 900 min
in increments of 5 min
(default setting: 300 min)
12
Interval of the
equalizing charge
30d
Can be set from 1 day to 90 days
in increments of 1 day
(default setting: 30 days)
13
Starting/stopping
equalizing charge
EEN
Starting equalizing charge
immediately
EDE
Stopping equalizing charge
immediately
14
Undervoltage for
disconnecting
load current
(under-voltage
cutoff)
11.5 V
12 V rated voltage:
Can be set from 9.0 V to 12.5 V
in increments of 0.1 V
(default setting: 11.5 V)
23.0
24 V rated voltage:
Can be set from 18.0 V to 25.0 V
in increments of 0.2 V
(default setting: 23.0 V)
46.0
48 V rated voltage:
Can be set from 36.0 V to 50.0 V
in increments of 0.4 V
(default setting: 46.0 V)
15
Voltage for
switching load
current on again
after under-
voltage cutoff
12.5 V
12 V rated voltage:
Can be set from 9.0 V to 12.5 V
in increments of 0.1 V
(default setting: 12.5 V)
25.0
24 V rated voltage:
Can be set from 18.0 V to 25.0 V
in increments of 0.2 V
(default setting: 25.0 V)
50.0
48 V rated voltage:
Can be set from 36.0 V to 50.0 V
in increments of 0.4 V
(default setting: 50.0 V)