Program selection Name
Option Meaning
16
Control of load
output
ON
On (default setting)
Load output is always switched
on, except in the event of under-
voltage cutoff
Switching off by pressing the
"Load on/off & ESC" button for
one second
OFF
Load output is always switched
off
Switching on by pressing the
"Load on/ switching & ESC"
button
LIG
Power-on time of the load output
is controlled by the settings in
program 18
The light function refers to the time of dusk and dawn, called sunset time and sunrise
time. If the detected PV input voltage is lower than the set value in program 19, this is
considered as dusk and the time is recorded as sunset time. If the detected PV input
voltage is 5 V higher than the set value in program 19, this is considered as dawn and
the time is recorded as sunrise time.
17
Mode for load
control
EVN
Evening light
If selected, the load output is
switched on after sunset and
remains switched on for the
duration set in program 19
MOR
Morning light
If selected, the load output is
switched on before sunrise and
remains switched on for the
duration set in program 19
NIT
Night light (standard)
If selected, the load output is
switched on for the entire night,
from the sunset time to the
sunrise time independently of the
setting in program 19