EN
13
3. Successively introduce the conductors into the screw-type terminals of the solar
charge controller and tighten the terminal screws.
4. Connect positive cable (+) of the battery to the battery positive input of the solar
charge controller.
5. Connect negative cable (-) of the battery to the battery negative input of the solar
charge controller.
6. Connect positive cable (+) of the solar module to the solar module positive input of the
solar charge controller.
7. Connect negative cable (-) of the solar module to the solar module negative input of
the solar charge controller.
8. Connect positive cable (+) of the consumer to the consumers circuit positive input of
the solar charge controller.
9. Connect negative cable (-) of the consumer to the consumers circuit negative input of
the solar charge controller.
10. Connect earth cable (at least AWG 8/10 mm²) to the earth connection of the solar
charge controller.
NOTE
No more than one of the negative terminals or one of the positive terminals of
the connections of the solar modules, of the battery, or of the load output
may be connected to earth.
6
Operation
NOTE
A battery must have been connected prior to switching on. The solar charge
controller does not work if a solar module but no battery is connected.
The operating panel consists of the display, three LEDs and three buttons:
1
Display
2
LEDs
3
"Load on/off & ESC" button
4
"Enter & Call settings menu" button
5