EN
31
Version
30 A
50 A
Battery charging
Max. charging current
30 A
50 A
Required battery capacity
Min. 60 Ah
Min. 100 Ah
Charging stages
3-stage, plus periodical equalizing charge:
Bulk-Absorption-Float
Charging voltage,
absorption charge (rated
value)
14.4 V / 28.8 V
14.4 V / 28.8 V / 57.6 V
Charging voltage, float
charge (rated value)
13.9 V / 27.8 V
13.9 V / 27.8 V / 55.6 V
Load disconnect in the
event of undervoltage
(rated value)
11.5 V / 23.0 V
11.5 V / 23.0 V / 46.0 V
Switch-on after
undervoltage
12.5 V / 25.0 V
12.5 V / 25.0 V / 50.0 V
Load disconnect in the
event of overvoltage
16.5 V / 33.0 V
16.5 V / 33.0 V / 66.0 V
Switch-on after
overvoltage
16.0 V / 32.0 V
16.0 V / 32.0 V / 64.0 V
Consumers circuit
Max. load current for
consumers
20 A
Voltage at the load output
Corresponds to the battery voltage
Consumers that require more than 20 A must be connected directly to the battery.
Inverters must not be connected to the load output.