Instruction Manual
22
Power Management (SV1108IPPOW only)
This section lets you set up the power management for the SV1108IPPOW’s
power switch.
The meanings of the field headings are given in the following table:
Click the Outlet icon to power operations
on and off. A green outlet icon indicates
that the power is currently On.
Confirmation Required
If this option is enabled (there is a check
in the checkbox), a dialog box comes up
asking you to confirm a power operation
before it is performed. If it is disabled
(there is no check in the checkbox), the
operation is performed
without confirmation.
Power On Delay
Sets the amount of time the
SV1108IPPOW waits after the Power
Button is clicked before it turns on the
power to the outlet.
NOTE:
The default delay time is 0
seconds; the maximum is 999 seconds.
Power Off Delay
Sets the amount of time the
SV1108IPPOW waits after the Power
Button is clicked before it turns off the
power to the outlet.
For the System after AC Back option
(see below), after the delay time expires,
the SV1108IPPOW waits another fifteen
seconds, then shuts the computer down.
The default delay time is 15 seconds. The