![Star Headlight & Lantern LCS790 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/star-headlight-and-lantern/lcs790/lcs790_installation-and-operating-instruction-manual_1362163035.webp)
-28-
Installation: Optional Settings
Horn Ring Transfer (HRT) Options
HRT Active Mode
By default, if you connect the Horn Ring Transfer (HRT) option (see Horn
Out and Auxiliary wires in wiring diagram on page 39), you can control the
siren any time it is on (see page 38).
If you would like this feature to be disabled until the slide switch or certain
buttons are activated, change this setting.
Place the PGM DIP switch in this position:
Up
Place the Rotary Knob in this position:
Radio
Place the Slide Switch in this position:
Off
And toggle this button:
S6
If
S6
is
Red
:
(Default setting)
The HRT function will operate any time the siren is on.
If
S6
is
Green
: The HRT feature will only operate when the buttons programmed
below are activated. (By default, if S6 is green, the HRT function will
be operational any time the Slide Switch is moved to
1
1
1
1
,
2
2
2
2
,
or
3
3
3
3
).
If S6 is red, flip the PGM DIP switch down to save the changes.
If S6 is green, you may need to proceed below to program the
functions necessary for the HRT to function. If the default setting of
any Slide Switch position activating HRT is acceptable, you can flip
the PGM DIP switch down to save the changes and skip the
Advance Slide Switch Programming section below.
—
–
–
A
d
v
a
n
c
e
d
S
li
d
e
S
w
it
c
h
P
ro
g
ra
m
m
in
g
—
–
—
If you need to select which buttons or slide switch positions will enable functioning
of the HRT mode, proceed below.
With the PGM DIP switch in this position:
Up
Place the Rotary Knob in this position:
RADIO
Place the Slide Switch in this position:
And toggle these buttons:
S1-S7, HORN, MAN
S1-S7
are
Green
:
(Default setting)
If any of the functions tied to each Green button
(S1-S7)
are activated, the HRT function is available.
HORN
is
Green
:
(Default setting)
If
SS
3
3
3
3
is activated, the HRT function is available.
MAN
is
Green
:
(Default setting)
If
SS
1
1
1
1
or
SS
2
2
2
2
is activated, the HRT function is
available.
S1-S7
are
Red
: These buttons
(S1-S7)
will have no effect on whether or not the
HRT function is available.
HORN
is
Red
:
Slide Switch Position
3
3
3
3
will have no effect on whether or not the
HRT function is available.
MAN
is
Red
: Function tied to
Slide Switch Position
1
1
1
1
and
Slide Switch
Position
2
2
2
2
will have no effect on whether or not the HRT function
is available.
Once you have programmed your option(s) to the desired setting(s),
you must
flip the PGM DIP switch down to save the changes.