Installation: Detailed Programming
Steady or Pulsed Output Options
Pulsed Output Rate
If you have set any of the outputs to pulse
(as described above), they will default
to a slow flashing pattern. If you would like your pulsed outputs to use a fast
flashing pattern, change this setting.
Place the PGM DIP switch in this position:
Up
Place the Rotary Knob in this position:
ALERT
Place the Slide Switch in this position:
Off
And toggle this button:
S1
Button is
Green
:
(Default setting)
Any pulsed outputs will flash slow.
Button is
Red
: Any pulsed outputs will flash fast.
Once you have programmed your option(s) to the desired setting(s),
you must
flip the PGM DIP switch down to save the changes.
Pulsed Output Phase
(for use with two or more pulsed outputs)
If you have set any of the outputs to pulse
(as described above), there are two
“phases” each can flash in (Phase 1 alternates with Phase 2). By default, all of
the outputs are set for Phase 1 (they will all flash “On” at the same time). If you
wish any of the outputs to flash in Phase 2 (opposite Phase 1), change this
setting.
Place the PGM DIP switch in this position:
Up
Place the Rotary Knob in this position:
WAIL
Place the Slide Switch in this position:
2
2
2
2
And toggle any of these buttons:
S1-S7
Button is
Green
:
(Default setting)
Output, if pulsed, will flash during Phase 1.
Button is
Red
: Output, if pulsed, will flash during Phase 2.
Once you have programmed your option(s) to the desired setting(s),
you must
flip the PGM DIP switch down to save the changes.
—
—
—
–
—
A
d
v
a
n
c
e
d
P
u
ls
e
d
O
u
tp
u
t
P
ro
g
ra
m
m
in
g
—
—
–
—
—
Steady or Flashing/Pulsed Outputs
The outputs switched by each push button normally apply 12 VDC.
If you would like any of these outputs to be flashing or pulsed (i.e. if you were
hooking it up to a light that didn’t have its own flasher), change this setting.
Place the PGM DIP switch in this position:
Up
Place the Rotary Knob in this position:
MAN
Place the Slide Switch in this position:
Off
And toggle any of these buttons:
S1-S7
Button is
Green
:
(Default setting)
The output will deliver 12 VDC.
Button is
Red
: The output will pulse +12 VDC.
Each button (
S1-S7
) can be programmed independently of the others. Under
normal operation, the buttons controlling any outputs programmed to flash, will
flash green.