User Interface
Indicator lights
Alarm indicator light
In-range indicator light
SLOW FLASH if there are active
alarms.
QUICK FLASH if there are fatal
alarms.
NORMAL FLASH when controlling
temperature probe is inside the
acceptable range
Constant ON after 30 min. in-
range
Alarm
In range
Red
Green
Both lights only active when the container is connected to a power supply line.
During power up both lights are shortly illuminated to verify their function.
A “Slow flash” is a short flash every 3 sec. A “Quick flash” is a flash every 1 sec. A NORMAL FLASH
is a flash every 1½ sec.
Display
Setpoint temperature
Control sensor temperature
Status text
Suction pressure
scale [bar]
Discharge pressure
scale [bar]
°C
/
°F unit
Secondary information
Icons
Setpoint control
C
RET
______
______
SETPOINT
CT
SUPPLY
C / F
Temperature and pressure unit selection
C Bar or Fahr Psi
Pre Trip Inspection or Function Test is running
Unit is operated in service mode
Humidity control is activated
Water cooled condenser is activated
Defrosting is running
Heater elements are switched on
Alarms are present in the alarm menu
CT
Setpoint is controlled by Cold Treatment, CT pro-
gram
MTS
Setpoint is controlled by Multiple Temperature
Set points, MTS program