xii
Commands
SR860 DSP Lock-in Amplifier
FFT Screen Commands
page description
FFTR(?) { ADC | MIXer | FILTer | i }
125 Set FFT data source
125 Set vertical scale from 1.0 dB (0) to 200 dB (7)
125 Set top reference level
126 FFT auto scale
126 Query maximum allowed frequency span in Hz/div
126 Set frequency span in Hz/div
FFTA(?) { AVG1 | AVG3 | AVG10 | AVG30 | AVG100 | i }
126 Set averaging
126 Turn FFT off/on (pause/live)
FCRW(?) { LIne | NARrow | WIde | i }
126 Set the cursor width
127 Query the FFT cursor frequency
127 Query the FFT cursor amplitude
Scan Commands
page description
SCNPAR(?) { Fint | REFAmp | REFDc | OUT1 | OUT2 | i }
128 Set the scan parameter
128 Set the scan type
SCNEND(?) { ONce | REpeat | UPdown | i }
128 Set the scan end mode
128 Set the scan time to x seconds
128 Set the amplitude attenuator mode for scanning
129 Set the dc attenuator mode for scanning
129 Set the scan parameter update interval
129 Turn the scan off/on
130 Start or resume the scan
130 Pause the scan
130 Reset the scan
130 Query the scan (off, reset, run, pause or done)(0-4)
SCNFREQ(?) [ BEGin | END | j ] { , f { HZ | KHZ | MHZ } }
130 Set the begin/end frequency
SCNAMP(?) [ BEGin | END | j ] { , v { NV | UV | MV | V } }
130 Set the begin/end reference amplitude
SCNDC(?) [ BEGin | END | j ] { , v { NV | UV | MV | V } }
130 Set the begin/end reference dc level
SCNAUX1(?) [ BEGin | END | j ] { , v { NV | UV | MV | V } }
131 Set the begin/end AuxOut1 value
SCNAUX2(?) [ BEGin | END | j ] { , v { NV | UV | MV | V } }
131 Set the begin/end AuxOut2 value
Data Transfer Commands
page
description
OUTR? [ DAT1 | DAT2 | DAT3 | DAT4 | j ]
132 Query data channel j
132 Query lock-in parameter j
132 Query multiple lock-in parameters at once
Data Capture Commands
page
description
136 Set the buffer length to n 1 kbyte blocks
CAPTURECFG(?) { X | XY | RT | XYRT | i }
136 Configure capture to X, XY, R
θ
or XYR
θ
(0–3)
136 Query the maximum capture rate
136 Set the capture rate to (max rate)/2
n
Содержание SR860
Страница 1: ...Revision 2 01 Operation Manual SR860 500 kHz DSP Lock in Amplifier ...
Страница 5: ...Safety and Preparation For Use iii SR860 DSP Lock in Amplifier ...
Страница 6: ...iv Safety and Preparation For Use SR860 DSP Lock in Amplifier ...
Страница 54: ...36 Getting Started Chapter 1 SR860 DSP Lock in Amplifier ...
Страница 118: ......
Страница 172: ......
Страница 186: ...168 The FFT Display Appendix B SR860 DSP Lock in Amplifier ...
Страница 192: ......
Страница 222: ...204 Circuit Description Appendix H SR860 DSP Lock in Amplifier Partial schematics follow this page ...