STACK ST8302 and ST8360 Video-Logger System
Chapter 5. Troubleshooting
User Guide
67
Symptom
Possible Cause
Remedy
Notes
Speed reading
dies after a short
time
Ambient temperature
too high
Shield the sensor
from radiated heat
from brakes and
bearings. Insulate
sensor from
conducted heat with
fibre washers. Duct
cooling air around
the sensor
Maximum
temperature for
correct operation of
the wheel speed
sensor is +80
°
C
(175
°
F)
All the alarms have
been switched off
Switch on the
required alarms
The Gate RPM value
is set too high
Reset the RPM gate
to a lower value
No alarms for
water, oil or fuel
(temperatures and
pressures) being
Displayed
Gate RPM test has
been switched off
Switch on the Gate
RPM test
Alarms only operate
when the engine is
running at or above
the gate RPM value
Video Display and
alarm light flash
when the engine is
running, Alarm
Counter
increments
constantly
Intermittent alarm
caused by a
parameter with its
alarm level set too
close to the normal
operating value
Either change the
value for the alarm
or turn the alarm off
Interference from
Ignition system & HT
Leads
Fit Suppressed
(Silicon) HT Leads.
Fit a suppression
capacitor (2.2uF)
between the coil
(battery connection)
& chassis
Use ‘Helical’
suppressed leads in
extreme cases
Video Display
works OK until
engine starts then
Video Display
freezes or resets
continuously.
Video Display
recovers once
engine stopped
Wiring too close to
HT leads and/or
injector leads, or HT
leads tied to isolated
metal work to which
Stack wiring is also
tied
Keep ALL wiring
away from HT leads
Low tension leads
on High
Performance
Ignition packs
& injector leads
Recommended
Minimum spacing
75mm (3.0”)