Chapter 5. Troubleshooting
STACK ST8302 and ST8360 Video-Logger System
62
User Guide
Symptom
Possible Cause
Remedy
Notes
A Pressure sensor
has failed
Replace sensor
Disconnect and
replace sensor with
a known good
sensor. If fault
continues then
check the harness.
Video Display
gives a floating
(slowly changing)
incorrect Pressure
reading.
Faulty harness
connections
Check continuity of
harness leads for
open circuits
Remove the sensor
& short MSS(P)
harness connector
pins 1& 4 together
A reading of -99 =
harness OK
Pressure sensor has
failed
Replace sensor
Swap with the other
pressure sensor to
confirm fault
Suspected low or
slow pressure
reading
Faulty pressure pipe
connections
Check pressure
connections
Check plumbing for
a blockage (kinks in
flexible hoses)
V Module shows a
different Fuel
Pressure reading
to the ST8100
Video Display,
Incorrect Fuel
Pressure sensor
selected
Select the Fuel
Pressure sensor to
match the ST8100
Sensors can be:
0-30psi / 0-2 Bar
0-150psi / 0-10 Bar
PEAK Switch faulty
Replace Video
Controller
Disconnect the
Video Controller. If
values return to
normal, replace the
Video Controller
All sensors show
fixed high values
Faulty switch wiring
Check switch wiring Check wiring for
short between 15w
connector pins A
and E (earth) or 8w
Switchcraft pins 3 &
8
Video Displays
pressure values
too low and
temperature
values too high
Low Battery voltage
Recharge battery
The system does
not give accurate
readings when the
voltage is below
8.0V
Содержание ST8302