STACK ST8302 and ST8360 Video-Logger System
Chapter 2. Getting Started
User Guide
23
Displaying the Peak Values
Press and hold the
PEAK
button
on the remote control to show the peak values
for the parameters currently being displayed.
The display changes, to show “PEAKS” instead of “STACK” while you are in this
mode.
Release the switch to return to the normal display.
Resetting the Peak Values
Peak values are reset automatically on a recorder with a LAN-C port,
when recording starts. On other types of recorder, you will need to
reset the peak values manually.
To reset the peak values hold down the PEAK button on the Remote Control
Unit and press RECORD. All peak values are reset at the same time.
If the engine is running
at
or
above
its Gate RPM Value (see Chapter 3 –
Configuration) when the peak values are reset, they are set to the current value
of each parameter.
If the engine is running
below
its Gate RPM Value, the peak values are not
reset to the current values but are set to the values shown in Table 5 instead:
Содержание ST8302
Страница 1: ...Part No Issue No ST542075 001 ST8302 and ST8360 Video Logger System Users Guide...
Страница 2: ......