ST 500 "Piranha" Operation Manual: General Information
7
Number in fig.2
Marking on the device
Element description
5
Sensor of the IR DETECTOR
6
ANT
Antenna socket of the SELECTIVE HF DETECTOR
7
INPUT
Electronic switch input
8
Prop
9
Info shield with serial number
10
Inbuilt speaker
11
Charger connected indicator
12
Charger socket
13
Mini-USB for PC connection
1.3.2. ELECTRONIC SWITCH
The device is equipped with an inbuilt electronic switch for a more efficient testing of multiwire
cables.
The automated and manual control of the electronic switch allow engaging all possible paired
combinations of cores in a multicore cable connected to the electronic switch (via RJ45 socket,
). While testing electric mains, control of the electronic switch is disabled.
1.3.3. ADAPTER FOR CONNECTING TO ELECTRIC MAINS
The adapter is intended for connecting the main unit to electric mains equipped with European
standard sockets (
). A LED indicator in the plug shows if the line is powered. The adapter
cable is equipped with an RJ45 connector, with only the first and second pins are engaged, and
the rest are disabled.
1.3.4. CABLE FOR CONNECTING TO COMPUTER SOCKETS (RJ45)
The cable is used for connecting the main unit to a computer line equipped with standard RJ45
connectors.
The cable (
) is a standard patch cord.
1.3.5. CABLE FOR CONNECTING TO TELEPHONE SOCKETS (RJ11)
The cable is used for testing telephone lines equipped with 6P4C sockets. The cable (
) is
equipped with 8P8C (RJ45) and 6P4C connectors. In the RJ45 connector, the four central pins
(## 3-6) are engaged, while the four side ones (## 1, 2, 7, 8) have no connections.
1.3.6. ADAPTER FOR CONNECTING A MULTICORE CABLE
The adapter (
) is used for connecting to raw-ended (not fitted with connectors) low
current cables. While connecting a raw-ended twisted pair cable, it is advised to observe the
wiring color scheme (