COMBUSTION AIR
1.
Under certain conditions it is recommended that the Element-P be connected to an
outside source of combustion air to improve performance. Flexible metal hose, or
rigid metal pipe, (conduit), must be connected around (NOT INSIDE) the combustion
air inlet tube. Be careful not to pinch or bend the outside air pipe with too small a
radius which may be terminated flush with the outside wall but should be protected
from wind and weather by a hood. Note: The outside air pipe must terminate above
the maximum snow line.
Optional Outside Air Kit 100354 is available to connect to
the intake damper.
Figure 16
2.
Outside air may be drawn from a semi-enclosed attic or crawl space or any semi-
enclosed space. Take care not to draw cold air past water pipes that may freeze.
3.
Increase the outside air pipe diameter to 3” for runs over ten (10) feet and elevation
over 4,000 feet. Note: Long runs should be avoided.
4.
Terminate the outside air pipe below the exhaust vent outlet.
5.
An open mesh screen should be placed over the outside air pipe opening to prevent
birds or rodents from nesting in the opening. Use an elbow or shield to prevent
prevailing winds from blowing directly into the outside air intake pipe. NOTE: Mesh
screen should be no smaller than one-fourth inch (1/4”) by one-fourth inch (1/4”).
WARNING: OUTSIDE COMBUSTION AIR IS REQUIRED FOR ALL MOBILE
HOME INSTALLATIONS!
WARNING
USE THE AIR INTAKE
DAMPER FOR
ADJUSTING
COMBUSTION INLET
AIR ONLY! OTHER
METHODS OF
RESTRICTING OR
BLOCKING
COMBUSTION INLET
AIR ARE STRICTLY
PROHIBITED!
Содержание Element-P
Страница 51: ...Element P 51 PARTS LAYOUT Figure 34 ...
Страница 52: ...Element P 52 Figure 35 PARTS LAYOUT ...
Страница 53: ...Element P 53 PARTS LAYOUT Figure 36 ...
Страница 54: ...Element P 54 PARTS LAYOUT Figure 37 Figure 38 ...
Страница 55: ...Element P 55 Sensor System Figure 39 Versa Grate Motor Assembly Figure 40 Figure 41 ...
Страница 56: ...Element P 56 Figure 42 ...