background image

1

Outdoor Lifestyles by Hearth & Home Technologies  •  Twilight-II-C Installation Manual  •  2368-970 Rev. C  •  2/15

Models:

Installation Manual

Installation and Appliance Setup

INSTALLER:  Leave this manual with party responsible for use and operation.
CONSUMER:  Retain this manual for future reference.

Twilight-II-C

NOTICE: DO NOT

 discard this manual!

This appliance may be installed as an OEM 
installation in manufactured home (USA 
only) or mobile home and must be installed 
in accordance with the manufacturer’s 
instructions and the 

Manufactured Home 

Construction and Safety Standard,

 

Title 24 

CFR, Part 3280 

in the United States, or the 

Standard for Installation in Mobile Homes, 
CAN/CSA Z240 MH Series,

 in Canada.

This appliance is only for use with the type(s) 
of gas indicated on the rating plate. This 
appliance is not convertible for use with other 
gases, unless a certi

fi

 ed kit is used.

In the Commonwealth of Massachusetts installation must be 
performed by a licensed plumber or gas 

fi

 tter.

See Table of Contents for location of additional Commonwealth 
of Massachusetts requirements.

DANGER

HOT GLASS 

WILL 

CAUSE BURNS.

DO NOT TOUCH 

GLASS 

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

 TO TOUCH GLASS.

A barrier designed to reduce the risk of 
burns from the hot viewing glass is provided 
with this appliance and shall be installed for 
the protection of children and other at-risk 
individuals.

• 

DO NOT

 store or use gasoline or other 

fl

 am-

mable vapors and liquids in the vicinity of this 

or any other appliance.

•  What to do if you smell gas   

DO NOT

 try to light any appliance.

DO NOT

 touch any electrical switch. 

DO 

NOT

 use any phone in your building.

-  Leave the building immediately.
-  Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup-

plier’s instructions.

-  If you cannot reach your gas supplier, call 

the 

fi

 re department.

•  Installation and service must be performed 

by a quali

fi

 ed installer, service agency, or the 

gas supplier.

WARNING: 

FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly 
could result in serious injury, death, or 
property damage. 

Содержание TWILIGHT-II-C

Страница 1: ...n must be performed by a licensed plumber or gas fitter SeeTable of Contents for location of additional Commonwealth of Massachusetts requirements DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of ...

Страница 2: ...nts for the Commonwealth of Massachusetts 6 2 Getting Started A Design and Installation Considerations 7 B Tools and Supplies Needed 7 C Inspect Appliance and Components 7 3 Framing and Clearances A Appliance Dimension Diagram 8 B Clearances to Combustibles 9 4 Termination Location and Vent Information A Chimney Diagram 11 5 Appliance Preparation A Removing Non combustible Facing Material Assembly...

Страница 3: ...ing for installation type ___________________________ Finishing Section 8 Pg 22 28 Combustible materials not installed in non combustible areas ___________________________ Veri ed all clearances meet installation manual requirements ___________________________ Mantels and wall projections comply with installation manual requirements ___________________________ Appliance Setup Section 9 Pg 29 33 Al...

Страница 4: ...rmal Resistance R Value Thermal Conductivity K Value 27 0 8hr sq ft ºF BTU 1 25 BTU in hr sq ft ºF Model Air Infiltration ASTM E283 Water Resistance ASTM E331 Structural Load ASTM E330 Twilight II C Indoor Outdoor 0 07CFM ft2 No leakage 8psf 25psf No Blowout 75psf B Glass Specifications Tempered Glass Interior Glass Hearth Home Technologies appliances manufactured with tempered glass may be instal...

Страница 5: ...erials I Electrical Codes NOTICE This appliance must be electrically wired and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition or the Canadian Electric Code CSA C22 1 A 110 120 VAC circuit for this product must be pro tected with ground fault circuit interrupter protection in compliance with the applicable electrical ...

Страница 6: ...izontally vented gas fu eled heating appliance or equipment The sign shall read in print size no less than one half 1 2 in in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OB STRUCTIONS Inspection The state or local gas inspector of the side wall horizon tally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector ob serves carbon monoxide detectors an...

Страница 7: ...a fan wall switch or remote control are desired C Inspect Appliance and Components Carefully remove the appliance and components from the packaging The vent system components and decorative doors and fronts may be shipped in separate packages If packaged separately the log set and appliance grate must be installed Report to your dealer any parts damaged in shipment particularly the condition of th...

Страница 8: ...B GAS LINE ACCESS C C D G H I J F E ELECTRICAL ACCESS U T MEASURE TO BOTTOM OF LIP AS SHOWN IN U R T Q S OUTDOOR VIEW P O L M INDOOR VIEW K N OUTDOOR OUTDOOR Location Inches Millimeter A 2 1 4 57 B 4 3 4 121 C 1 2 13 D 43 1092 E 24 610 F 46 7 8 1191 G 46 7 8 1191 H 9 1 2 241 I 2 1 2 64 J 4 1 2 114 K 32 5 8 829 Location Inches Millimeter L 36 1 4 921 M 41 7 8 1064 N 21 1 2 547 O 6 1 8 155 P 38 5 8 ...

Страница 9: ...ssed into the framing GLASS EXTERIOR INSULATED ENVELOPE GLASS A B B D C 24 INCH MAX B GLASS FLUSH TO EXTERIOR INSULATED ENVELOPE GLASS E C NOTE Appliance may be installed flush on exterior interior or anywhere in between Any projection of the appliance interior or exterior must have a properly constructed chase surround ing the appliance The exterior must have proper insulating flashing and finish...

Страница 10: ... barriers or exposed insulation Prevent contact with sagging or loose insulation Locate and install appliance to all clearance specifications in manual The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace Failure to maintain airspace may cause overheating and a fire Reference Figure 3 2 Figure 3 3 and Figure 3 4 for cl...

Страница 11: ...located between two single family dwellings and serves both dwellings Electrical Service V K V K V L C V N 6 inches non vinyl sidewalls 12 inches vinyl sidewalls O 18 inches non vinyl soffit and overhang 42 inches vinyl soffit and overhang P 8 ft Covered Alcove Applications Spaces open only on one side and with an overhang CAUTION Risk of Burns Terminations are HOT consider proximity to doors traf...

Страница 12: ...MPERATURE SEALANT 300 F 149 C min BOTH SIDES APPLIANCE EXTERIOR A Removing Non combustible Facing Ma terial Assembly The non combustible assembly is located on right hand side of appliance when looking from outdoor side of appliance 1 Hold non combustible pieces in place 2 Remove and save two screws from upper bracket 3 Remove non combustible pieces 4 Remove and save three screws from lower bracke...

Страница 13: ... the appliance from side to side and front to back Shim the appliance as necessary It is acceptable to use wood shims Keep nailing tabs flush with the framing Secure the appliance to the framing by using nails or screws through the nailing tabs Placing Flashing and Sheathing Apply high temperature silicone sealant to corner edges of fireplace flange See Figure 5 3 Figure 5 3 Figure 5 4 Install out...

Страница 14: ...ble finishing material can be up to a maximum of 6 inches thick 6 inches maximum horizontal overhang to allow for brick and stone alcoves see Figure 5 5 NOTE Combustible house wrap or building paper MUST NOT extend over the outside of non combustible sheath ing and MAY extend over the flashing behind non com bustible sheathing a maximum of 1 inch Use high temp silicone or sealant recommended by th...

Страница 15: ...bustible finishing materials per manu facturer s instructions Figure 5 9 Complete Installation of Non combustible Facing Material Outdoor Side Fire Risk Follow these instructions exactly Facing materials must be installed properly to prevent fire No materials may be substituted without authorization by Hearth Home Technologies Center and attach two top boards the two shorter pieces to the framing ...

Страница 16: ...ed within the same wall box 6 6 Electrical Information Figure 6 1 Junction Box Detail NOTICE DO NOT wire 110 120 VAC to wall switch GREEN WIRE INSIDE BOX 14 2WG COPPER GROUND ATTACHED TO GRN SCREW WITH GRN WIRE BLK WHT WHT BLK HEAT SHIELD Junction Box Installation If the box is being wired from the OUTSIDE of the appliance Install the Romex connector not included with appliance in the side wrap Lo...

Страница 17: ...re 6 2 Fan Installation To provide best airflow we recommend positioning fan on the left side as viewed from appliance interior side see Figure 6 3 NOTE It is recommended fan be in stalled prior to gas line installation for ease of installation Wall Switch Position the wall switch in the desired position on a wall Run a maximum of 25 feet 7 8 m or less length of 18 A W G minimum wire and connect i...

Страница 18: ...former Remove batteries before using the transformer and unplug the transformer before installing the batteries Battery polarity must be correct or module damage will occur Figure 6 4 Intellifire Pilot Ignition IPI Wiring Diagram NOTE 1 Ignition module valve pilot and wall switch operate on 3 volts Uninterrupted 120 VAC is required at junction box unless equipped with battery back up IGNITION MODU...

Страница 19: ...h ground wire At the switch box connect the black hot wire and red switch leg wire to the wall switch as shown At the appliance connect the black hot white neutral and green ground wires to the junction box as shown Add a 1 4 in insulated female connector to the red switch leg wire route it through the knockout in the face of the junction box and connect to the top fan switch connector 1 4 in male...

Страница 20: ...Risk of Fire Explosion or Asphyxiation Check all fittings and connections with a non corrosive commercially available leak check solution DO NOT use open flame Fittings and connections could have loos ened during shipping and handling WARNING Risk of Fire DO NOT change valve settings This valve has been preset at the factory WARNING Risk of Fire or Explosion High pressure will damage valve Low pre...

Страница 21: ... E Air Shutter Setting Air shutter settings should be adjusted by a qualified ser vice technician at the time of installation The air shutter is set at the factory NOTICE If sooting occurs provide more air by opening the air shutter Air Shutter Settings Twilight II C NG 3 8 in Twilight II C LP Full Open ...

Страница 22: ...se fire 12 11 10 9 8 7 6 13 5 8 12 5 8 11 5 8 10 5 8 9 5 8 8 5 8 7 5 8 HOOD NON COMBUSTIBLE BOARD SUPPLIED ON APPLIANCE INDOOR SIDE ONLY CEILING 35 3 4 MEASUREMENTS FROM TOP EDGE OF THE OPENING MEASURED FROM CORNER TOP VIEW FIREPLACE HOOD 1 2 IN Note Measurements are in inches Figure 8 1 Clearances to a Combustible and or Non combustible Indoor Mantel Figure 8 2 Clearances to a Combustible and or ...

Страница 23: ...lled Off the Floor FS TWI Decorative Front Application If the appliance is installed on the floor or level with an elevated hearth the FS TWI decorative front MUST be used The TWI MOD decorative front is not compatible with this type of installation as a minimum elevation of 3 4 inch is required on the bottom of the appliance TWI MOD Decorative Front Application If the appliance is installed at a ...

Страница 24: ...al 2368 970 Rev C 2 15 DECORATIVE FRONT DIMENSION DIAGRAM TWI MOD A B F E H G D C I BOTTOM OF APPLIANCE A B C D E F G H I TWI MOD in 37 43 3 8 30 3 4 20 3 8 33 38 3 4 6 3 8 2 3 8 1 2 mm 940 1102 781 518 838 984 162 6 13 Figure 8 6 Decorative Front Dimensions TWI MOD Decorative Front ...

Страница 25: ...es Twilight II C Installation Manual 2368 970 Rev C 2 15 Figure 8 7 Decorative Front Dimensions FS TWI Decorative Front DECORATIVE FRONT DIMENSION DIAGRAM FS TWI A C B D E A B C D E FS TWI in 36 1 16 31 1 8 31 3 4 25 7 8 1 3 4 mm 916 790 806 657 32 ...

Страница 26: ...e Risk Finish all edges and fronts to clearances and specifications listed in manual Black metal columns may be covered with non combustible material only Do NOT overlap combustible materials onto appliance front Install combustible materials only up to specified clearances on top front and side edges Seal joints between the finished wall and appliance top and sides using only a 300 ºF minimum sea...

Страница 27: ...E FACING MATERIAL AND APPLIANCE FRONT 6 in MAXMUM PROJECTION FROM FACE OF FIREPLACE BRICK LEDGE NON COMBUSTIBLE SHEATHING SUPPLIED COMBUSTIBLE SHEATHING HOUSEWRAP REQUIRED FLASHING SUPPLIED HOUSE WRAP EXHAUST Figure 8 11 Exterior View NOTE All finishing materials on top of exterior sheathing must be non combustible for a minimum of 10 7 8 inches above and on both sides of the exterior face of the ...

Страница 28: ...MANTEL OR CEILING 12 in MINIMUM CLEARANCE TO NON VINYL SIDING 36 in MINIMUM CLEARANCE TO VINYL SIDING DRAIN PLANE DETERMINED BY LOCAL CODE BRICK OR OTHER NON COMBUSTIBLE FACING MATERIAL 6 INCH MAXIMUM PROJECTION FROM SURFACE OF FIREPLACE INCLUDES NON COMBUSTIBLE MANTEL PROJECTION NON COMBUSTIBLE BRICK LEDGE MUST BE TIGHT TO APPLIANCE FACE OR NON COMBUSTIBLE SHEATHING TOP OF HOOD INSULATION Figure ...

Страница 29: ...lass Assembly Interior Loosen two wing nuts on bottom glass retainer bracket Loosen and remove two wing nuts on top glass retainer bracket Remove glass retainer bracket See Figure 9 1 Lift glass assembly off of glass retainer bracket Replacing Fixed Glass Assembly Interior Position glass assembly on bottom glass retainer bracket Tighten wing nuts on bottom glass retainer bracket Position top of gl...

Страница 30: ...ement WARNING Risk of Explosion Follow ember placement instructions in manual DO NOT place embers directly over burner ports Replace ember material annually Improperly placed embers interfere with proper burner operation Placing Lava Rock Place lava rock on refractory support pan Cover entire support pan surface see Figure 9 5 Figure 9 5 Placement of Lava Rock Removing Fixed Glass Assembly Exterio...

Страница 31: ...own above Position the thin end of log 1 one inch from port pattern as shown STEP 3 LOG 2 SRV2005 700 Position log 2 on the left grate bar and the pilot assembly Use the cut out notches on the log to position it as shown STEP 1 Before positioning the logs refer to the installation manual for electric ember set up and ember placement 1 1 2 2 PILOT PILOT ASSEMBLY ASSEMBLY CUTOUT CUTOUT GRATE BAR CUT...

Страница 32: ... log 4 against the grate tine as shown The smooth cutout on the bottom of log 4 should rest on the burner surface The side of Log 4 must be 3 4 inch from the nearest port hole on the right side of log 4 DO NOT cover any port holes STEP 6 LOG 5 SRV2005 704 Using the sharp notch on the heavy end of log 5 align it on the grate tine and set it on the flat area of log 4 as shown 3 3 4 4 SHARP SHARP NOT...

Страница 33: ...mbly Installed Notch engaged with Notch engaged with grate tine grate tine G Install Trim and or Surround Install optional trim kits and or surrounds using the instructions included with the accessory Use non combustible materials to cover the gap between the sheet rock and the appliance when applicable to the model F Appliance Start Up After appliance is completely set up replace glass assembly a...

Страница 34: ...th the barrier removed Contact your dealer or Hearth Home Technologies if the barrier is not present or help is needed to properly install one For more information refer to the instructions supplied with your decorative door or front Install approved accessories per instructions included with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shoc...

Отзывы: