Element-P
31
Changing the program on the Control Board
To change the Program, the Stove must be in the OFF
position and the unit must be completely cooled
down so the Proof of Fire Switch is Open and the
Thermostat slide switch must be in the Manual mode.
(See figure 21)
Press & hold
the Auger Feed Button, then press the
Trim
High & Low
Button at the same time. The LED
lights that indicate the heat level will flash. The
number of times the lights Flash will indicate which
program is running.
Program 1 – LED lights flash
once
Program 2 – LED lights flash
twice
Program 3 –LED lights flash
three times
Program 4 – LED lights flash
four times
Figure 21
Lighting Your Element-P with the Versa Grate System. (Program 3 & 4
only)
1. Make sure there are pellets in the hopper and the viewing door and ash pan door are
closed.
2. Push the On/Off button on the control board. (
See figure 21)
Monitor the burn pot to make sure the stove starts up properly. Once the On/Off button
has been pushed the Start Up program takes over.
The Start up Program works as follows:
a.
The Combustion fan and Room fan come on at high speed and the control board
checks to make sure the Vacuum switch locks in. (See Diagnostic features on
page 33 through 35)
b.
When the board senses the Vacuum switch the Combustion fan drops to the #1
setting and the Room fan shuts off.
Содержание Element-P
Страница 51: ...Element P 51 PARTS LAYOUT Figure 34 ...
Страница 52: ...Element P 52 Figure 35 PARTS LAYOUT ...
Страница 53: ...Element P 53 PARTS LAYOUT Figure 36 ...
Страница 54: ...Element P 54 PARTS LAYOUT Figure 37 Figure 38 ...
Страница 55: ...Element P 55 Sensor System Figure 39 Versa Grate Motor Assembly Figure 40 Figure 41 ...
Страница 56: ...Element P 56 Figure 42 ...