Hearth Mount
Legend
A – Vertical Cap
B – Chimney Flashing
C – Positive Block Off Plate
D – Stainless Steel Liner / PL Vent System
E – PL Tee or Single Wall Tee
F – Outside Air Shield – May be needed
G – 2” Metal Outside Air Pipe - Optional
Figure 9
Venting to the Top of Chimney
When installing as a hearth mount stove into a fireplace, the unit must either be relined
terminating above the chimney chase top, or positively connected to the existing chimney
system using a block off plate (C). An approved flex liner or PL vent must be used.
A
chimney system with known drafting problems may require a liner, which may also
need to be insulated to keep vent system warm in a cold chimney environment.