________________________________________________________________________________________________________________________________________________________________________________________________________________________
07-02-10-01-E-V0304.doc
Product Manual Type:
637f
63
7
Setting and programming
7.1 Jumper
All jumpers are set to a standard position in production !
JP100,
bridged pad...
2 and 3
(standard)
READY contact with reference to
common output supply voltage on X10.21
1 and 3
READY contact can be wired freely
JP101,
bridged pad...
2 and 3
(standard)
Analog input X10.19 without internal Pull-
up.
1 and 3
Analog input X10.19 with internal Pull-up
to +12 V
(FRR compatible)
JP102,
bridged pad...
2 and 3
(standard)
X10.23 = active ok. output
1 and 3
X10.23 = GND internal
(FRR compatible)
JP1, JP2
bridged pad...
adjust identically !
2 and 3
(standard)
X10.15 = high-active
1 and 3
X10.15 = low-active
JP3, JP4
bridged pad...
adjust identically !
2 and 3
(standard)
X10.14 = high-active
1 and 3
X10.14 = low-active
JP2.8, JP2.3
JP2.7, JP2.2
open
Default, RP CAN, RP DEV, RP PDP
RP 2CA, RP 2C8
close
RP 232, RP 422, RP 485,
RP IBS, RP EA5, RP SUC
7.2 Digital
communication
see chapter 13