General technical data
11.6 Digitale
communication
RS232 - service interface
COM1
19200 baud, 8 databits, 1 startbit, 1 stopbit,
parity: even
Optional
RS232 / RS422 / RS 485
on SUB D – socket
COM2
CAN1, Profibus DP, SUCOnet K
on SUB D – socket
Interbus S on SUB D – socket (OUT)
Interbus S (Remote IN)
CAN2
additional on SUB D – socket
11.7 Resolver
evaluation/transmitter principle
General:
The specified data refer to the combination of the standard resolver interface with Function-Module
X300_RD2; operated with the SSD Drives resolver R 21-T05, R15-T05
carrier frequency
ft = 4,75 kHz
ripple of the speed actual value
signal
2%
1)
max. position resolution for one
revolution
65536 / 16 bit
absolute position accuracy
+/- 0,7 °
1)
relative position accuracy
+/- 0,08 °
1)
1)
Data under check, Reality: Quality improved