Product Manual Type:
637f
07-02-10-01-E-V0304.doc
1.3 Range
data
1.3.1
Insulation concept
COM1
COM2
Rem ote IN
X10
analog
X10
digital
X40
X30
dep. Optionsmodule
M1, M2, M3
DC-bus
brak - cirquit
L1, L2, L3
Us DC 24 V
power supply
DC 24 V
PE
L1
N
AC
power - terminals
double insulation VDE 0160
Insulation of control voltage supply
Required for safe separation (PELV): double insulation
Take Care ! The insulation of control (Com1..X40) depends on the insulation of control voltage supply
Additional insulation via opto-coupler or relay (without Safety-Functions)
customer part
1)
1)
see additional hints, chapter 2.4.2
GND
1.3.2 General
data
Enclosure Rating
(for mounting in cubicle)
IP20
operating temperature range
EN 50178 / VDE 0160, class 3K3
storage temperature range
-25°...+55° C
air pressure
86 kPa - 106 kPa
Humidity
5% - 85%, 40°C
Operating Temp
0...40°C
reduced
operation
derating of the output current
1)
>40°...< 50°C
2% /°C
Altitude h
h
≤
1000m
reduced
operation
Derating of the output current
1)
h > 1000...
≤
4000m
1% / 100m
Safety Overvoltage-category of power circuit
EN 50178 / VDE 0160, UL, cUL III,
Pollution degree for mounting in cubicle
VDE / UL: 2
Vibration test in accordance with
DIN IEC 68-2-6, test FC
Condition for testing
Frequency
range
Amplitude
Acceleration
Test time per axis
Frequency sweep speed
10...57Hz 57...150Hz
0,075 mm
1g
10 sweep cycle
1 Oktave/min
1)
Use only fan-cooled devices. For reduced operating
conditions, no UL-Approbation are available.