Installation and Reference Manual
Maintenance & Troubleshooting
Installation and Reference Manual v3.2/0410/6
253
ftp <ip address of Call Server>
eg ftp 192.168.0.1
2
At the User prompt enter
admin
, then press Enter
3
At the Password prompt enter the Maintainer Password, eg password, then press Enter
The following FTP commands can then be used.
get a
- get file from the current directory and place in root, eg C:\
put a
- put file from root, eg C:\, into the current directory
mget B*
- will attempt to get all files from the FTP and ask you if you want them (y/n)
mode image
- switch to binary file transfer
hash
- show progress
quit
- exit
tftp
- trivial file transfer protocol eg tftp –g –l frog –r frog 192.168.0.1
Reset Switch
The Reset Switch on the front of a module can be used to assist with troubleshooting the SpliceCom
system.
Orderly Shut down of the File System
It is important to shut down the file system within the Call Server before removing power.
1
Press the Reset Switch once.
2
The file system will start to shut down
3
After about 10 seconds the LEDs on the front of the Call Server will flash and turn off
4
The SpliceCom LED will flash slowly to indicate that the shut down is complete.
5
At this point the power can be removed.
An orderly shutdown of the Call Server is also required before a Reboot and when defaulting the
database as explained below.
An orderly shut down of a Phone and Trunk module will also be required when performing a reboot and
upgrade as explained from page 260.
Reboot (Warm Start)
A reboot of a module may be required to restore connection to the LAN, restore connection to the Call
Server etc.
1
Firstly perform an orderly shut down as explained above.
2
When the SpliceCom LED is flashing press the Reset Switch once (or no more than 3 times).
3
The LED will turn off for 10 seconds and then flash rapidly as the system restarts. Alternatively wait
for 60 seconds the module will automatically restart.
Содержание Maximiser
Страница 1: ...Installation Reference Manual Version 3 2 April 2010 ...
Страница 6: ......