IM-P309-02
MI Issue 2
44
15.1.10 Display mode during startup
By choosing the Display mode during startup function the operator can define the default
display. After the operator switched the device on and did not touch any keys for a longer
period of time, the defined default display will be shown.
Display mode
(QV)
According to the description in Section 14.1.3.1 "Selection window / make a selection", one
of the following default displays can be selected.
QV (volume flow rate),
Counter 1 forward flow,
Counter 2 forward flow,
Counter reverse flow,
Velocity,
QVabs + QVrel,
QV + counter 1,
QV + counter 2,
QV + velocity,
and raw values.
15.1.11 Raw values
The "Raw value display" supports fault diagnostics and trouble shooting. Please inform our
service department about the clear text error messages and contents of the "Raw value
display".
xxx.xxx ggooo
iiii gguuu
The displayed values are decimals and have the following meaning:
xxx.xxx: Is a gauge for the measured electrode voltage.
ggooo: Is a gauge for the upper value of the reference calibration.
iiii:
Is a gauge for the current to generate the field coil’s magnetic field.
gguuu: Is a gauge for the lower value of the reference calibration.