8.3.4 Torques for studs and nuts
Electromagnetic flowmeters must be installed in the pipe system with special care due to the
fact that the flow pipe lining is made of PTFE which is malleable under pressure.
If the flange nuts are tightened too much, the sealing surface will deform. If the seals are
supposed to function properly, the correct torque is highly important.
Tighten the nuts crosswise, so that the process connections are tight. When tightening the
nuts for the first time, approximately 50% of the required torque should be reached, and for
the second time, the torque should be 80%. The required torque should reach 100% when
the nuts are tightened for the third time. For higher torques it is advisable to use protectors.
The following tables state the maximum torques:
Nominal size
(mm)
DIN Pressure
rating (bar)
Studs
Maximum torques
(Nm)
DN25
PN40
4 x M12
25
DN32-40
PN40
4 x M16
45
DN50
PN40
4 x M16
65
DN65
PN16
4 x M16
85
DN80
PN16
8 x M16
55
DN100
PN16
8 x M16
55
DN150
PN16
8 x M20
100
DN200
PN16
12 x M20
95
Nominal size
(inch)
ASME Pressure
rating (lbs)
Studs
Maximum torques
(Nm)
1"
Class 300
4 x ⅝"
15
1 ¼"-1 ½"
Class 300
4 x ¾"
35
2"
Class 300
8 x ⅝"
25
2 ½"
Class 150
4 x ⅝"
85
3"
Class 150
4 x ⅝"
80
4"
Class 150
8 x ⅝"
55
6"
Class 150
8 x ¾"
105
8"
Class 150
8 x ¾"
145
Содержание ELM