118153-001 Rev. B
28
uX_Manual.doc REV -
5.5 Response
Overview
The command responses will follow the same format as outlined above in
section 6.1. This list is comprised of Commands with complex responses
only. Commands using a simple response will use the <$> character
(ASCII 0x24) as a “Success” response or a single character error code.
These responses will be eight ASCII characters in length.
Response Name
<CMD>
Response
Request DAC A
Setpoint
14
11 ASCII
Request DAC B
Setpoint
15
11 ASCII
Request DAC D
Setpoint
16
11 ASCII
Request DAC C
Setpoint
17
11 ASCII
Request Analog
Readbacks Ch 7-15
19
24-51 ASCII
Request Analog
Readbacks Ch 0-6
20
20-41 ASCII
Request Total Hours
High Voltage On
21
14 ASCII
Request Status
22
12 ASCII
Request MCU
Software Version
23
18 ASCII
Request Hardware
Version
24
10 ASCII
Request Web Server
Version
25
18 ASCII
Request Model
number
26
12 ASCII
Request Expanded
Status
32
12 ASCII
Read Interlock Status
55
12 ASCII
Read Aux KV
Feedback
65
8-11
ASCII
Read SVN Revision
66
8-11
ASCII
Содержание uX SERIES
Страница 11: ...uX MANUAL 4 118151 001 REV A Figure 2 1 50kV uX DIMENSIONS ...
Страница 12: ...uX MANUAL 5 118151 001 REV A Figure 2 2 65kVuX DIMENSIONS ...
Страница 16: ...uX MANUAL 9 118151 001 REV A Table 3 2 DC Input Filament Connections ...
Страница 17: ...uX MANUAL 10 118151 001 REV A Figure 3 3 Monitors Voltage Current Control Connections ...
Страница 18: ...uX MANUAL 11 118151 001 REV A Figure 3 4 Recommended Interlock HV on Configurations ...