Spectra 1759MG
- 9 -
Programming Guide
Programmable Outputs
Each PGM Deactivation event can be used as another start (activation) event if their respective PGM timer (see sections
[066]
to
[068]
) is programmed with a value other than 000.
Example: section
[120]
= 05 03 02: this means PGM1 will activate whenever partition 2 is Stay Armed.
Section #
Event Group # Sub-Group #
Partition #
[120]
PGM 1 PGM Activation Event
___/___
___/___
___/___
[121]
PGM 1 PGM Deactivation Event
___/___
___/___
___/___
[122]
PGM 2 PGM Activation Event
___/___
___/___
___/___
[123]
PGM 2 PGM Deactivation Event
___/___
___/___
___/___
[124]
Global PGM Activation Event
___/___
___/___
___/___
[125]
Global PGM Deactivation Event
Used to activate PGMs on
expansion modules & LCD keypads
.
___/___
___/___
___/___
Event Group #
Sub-Group #
00 = Zone OK
01 to 15 = Zones 1 to 15
99 = Any Zone
01 = Zone Open
01 to 15 = Zones 1 to 15
99 = Any Zone
02 = Partition Status
00 = System not ready (
Partition 1 only
)
01 = System ready (
Partition 1 only
)
02 = Steady Alarm in Partition
03 = Pulsed Alarm in Partition
04 = Pulsed or Steady Alarm in Partition
05 = Alarm in Partition Restored
06 = Bell Squawk Activated (
Partition 1 only
)
07 = Bell Squawk Deactivated (
Partition 1 only
)
08 = Ground start (
Partition 1 only
)
09 = Disarm Partition
10 = Arm Partition
11 = Entry Delay (breach when system is armed)
99 = Any Sub-Group
05 = Non-Reportable Events
00 = Telephone Line Trouble (
Partition 1 only
)
01 = [
PG
] or [
FNC1
] key was pressed (
Partition 1 only
). This
option can also be used to reset smoke detectors.
02 = Instant Arming
03 = Stay Arming
04 = Force Arming
05 = Fast Exit (Force & Regular Only)
06 = PC Fail to Communicate (
Partition 1 only
)
07 = Midnight (
Partition 1 only
)
99 = Any Sub-Group (
Partition 1 only, except 02 to 05
)
06 = Arm/Disarm with Remote Control
01 to 08 = Remote Controls 1 to 8
99 = Any Remote Control
07 = Button Pressed on Remote
(see button option “B” on page 25)
01 to 08 = Remote Controls 1 to 8
99 = Any Remote Control
08 = Button Pressed on Remote
(see button option “C” on page 25)
01 to 08 = Remote Controls 1 to 8
99 = Any Remote Control
01 = Partition 1
02 = Partition 2
99 = Any Partition
The Sub-Groups proceeded by
“(Partition 1)” cannot be
assigned to activate Partition 2.
Содержание 1759MG
Страница 2: ......