Spectra 1759MG
- 8 -
Programming Guide
System Timers
Section #
Decimal Value (000 to 255)
Description
Default
[050]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
1)
600 msec.
[051]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
2)
600 msec.
[052]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
3)
600 msec.
[053]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
4)
600 msec.
[054]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
5)
600 msec.
[055]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
6)
600 msec.
[056]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
7)
600 msec.
[057]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
8)
600 msec.
[058]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
9)
600 msec.
[059]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
10)
600 msec.
[060]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
11)
600 msec.
[061]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
12)
600 msec.
[062]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
13)
600 msec.
[063]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
14)
600 msec.
[064]
___/___/___ x 10 msec.
ZONE
SPEED
(
ZONE
15)
600 msec.
[065]
F
UTURE
U
SE
[066]
___/___/___ seconds (000 = follow Deactivation Event)
PGM
1
TIMER
5 sec.
[067]
___/___/___ seconds (000 = follow Deactivation Event)
PGM
2
TIMER
5 sec.
[068]
___/___/___ seconds (000 = follow Deactivation Event)
GLOBAL
PGM
TIMER
5 sec.
[069]
___/___/___ seconds
ENTRY
DELAY
1
45 sec.
[070]
___/___/___ seconds
ENTRY
DELAY
2
45 sec.
[071]
___/___/___ seconds
EXIT
DELAY
1
30 sec.
[072]
___/___/___ seconds
EXIT
DELAY
2
30 sec.
[073]
___/___/___ minutes (000 = no bell on alarm)
BELL
CUT
-
OFF
TIMER
(
PARTITION
1)
4 min.
[074]
___/___/___ minutes (000 = no bell on alarm)
BELL
CUT
-
OFF
TIMER
(
PARTITION
2)
4 min.
[075]
___/___/___ x 15 minutes (000 = disabled)
NO
MOVEMENT
TIMER
(
PARTITION
1)
Disabled
[076]
___/___/___ x 15 minutes (000 = disabled)
NO
MOVEMENT
TIMER
(
PARTITION
2)
Disabled
[077]
___/___/___ seconds (minimum 10 sec.)
ANSWERING
MACHINE
OVERRIDE
DELAY
Disabled
[078]
___/___/___ (000 = no answer, maximum = 15 rings)
NUMBER
OF
RINGS
8 rings
[079]
___/___/___ x 2 sec. (minimum 32 sec.)
TLM
FAIL
TIMER
32 sec.
[080]
___/___/___ seconds
DELAY
ALARM
TRANSMISSION
Disabled
[081]
___/___/___ (000 = 16, maximum = 16)
MAXIMUM
DIALING
ATTEMPTS
8 attempts
[082]
___/___/___ seconds
DELAY
BETWEEN
ATTEMPTS
20 sec.
[083]
___/___/___ seconds
PAGER
DELAY
5 sec.
[084]
___/___/___ seconds (minimum 10 sec.)
INTELLIZONE
DELAY
48 sec.
[085]
___/___/___ seconds
RECENT
CLOSING
DELAY
No delay
[086]
___/___/___ minutes
POWER
FAILURE
REPORT
DELAY
15 min.
[087]
___/___/___ days (000 = disabled)
AUTO
TEST
REPORT
Disabled
[088]
___/___/___ 000 to 127 = +1 to +127 seconds
128 to 255 = -1 to -127 seconds
CLOCK
ADJUST
Disabled
[089]
___/___/___ (000 = disabled, maximum = 15)
AUTO
ZONE
SHUTDOWN
COUNTER
5
[090]
___/___/___ minutes (000 = disabled)
RECYCLE
ALARM
DELAY
Disabled
[091]
___/___/___ (000 = disabled)
RECYCLE
ALARM
COUNTER
Disabled
[092]
___/___/___ attempts before locking (000 = disabled)
KEYPAD
LOCKOUT
Disabled
[093]
___/___/___ minutes (000 = disabled)
KEYPAD
LOCKOUT
DELAY
Disabled
[094]
___/___/___ seconds (000 = disabled)
PANIC
LOCKOUT
TIMER
Disabled
[095]
___/___/___ days (000 = disabled)
CLOSING
DELINQUENCY
TIMER
(
PARTITION
1)
Disabled
[110]
___/___ : ___/___ hours (00 to 23) : minutes (00 to 59)
___/___ : ___/___ hours (00 to 23) : minutes (00 to 59)
___/___ : ___/___ hours (00 to 23) : minutes (00 to 59)
AUTO
TEST
REPORT
(
TIME
OF
DAY
)
Disabled
[111]
AUTO
-
ARM
TIME
(
PARTITION
1)
Disabled
[112]
AUTO
-
ARM
TIME
(
PARTITION
2)
Disabled
Содержание 1759MG
Страница 2: ......