![Spectra 1759MG Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/spectra/1759mg/1759mg_system-programming-manual-and-scpi-reference_1343207005.webp)
Spectra 1759MG
- 5 -
Programming Guide
Data Display Mode (LED Keypads Only)
View the section’s programming one digit at a time. Does not function with sections using Feature Select Programming.
Configuring the 1686H, 1686V and 1689 Keypads (V2.0 or higher)
The keypad’s zone number, EOL definition and anti-tamper switch are programmed through the keypad’s programming
mode. To do so:
PLEASE NOTE: After two minutes, the keypad exits programming mode.
Key [1] - Keypad Zone Selection
Key
[1]
determines whether the keypad’s zone is Keypad Zone 1 or Keypad Zone 2. When key
[1]
is OFF (not illuminated),
the keypad’s zone is Keypad Zone 1. When key
[1]
is ON (illuminated), the keypad’s zone is Keypad Zone 2. Refer to the
on page 6 for more information.
Key
[1]
OFF - Keypad Zone 1 (default)
Key
[1]
ON - Keypad Zone 2
Key [2] - EOL Definition
Key
[2]
determines the keypad zone’s EOL definition. When key
[2]
is OFF (not illuminated), EOL is disabled and the keypad
zone uses the on-board EOL resistor. When key
[2]
is ON (illuminated), EOL is enabled and the keypad zone requires that an
external EOL resistor be connected (refer to
on page 38 for more details).
Key
[2]
OFF - EOL disabled
Key
[2]
ON - EOL enabled (default)
Key [3] - On-Board Tamper
Key
[3]
enables or disables the keypad’s on-board anti-tamper switch. When key
[3]
is OFF (not illuminated), the anti-tamper
switch is disabled. When key
[3]
is ON (illuminated), the anti-tamper switch is enabled.
Key
[3]
OFF - On-board anti-tamper switch disabled
Key
[3]
ON - On-board anti-tamper switch enabled
PLEASE NOTE: The keypad can be ordered with or without an anti-tamper switch. If the keypad has no anti-
tamper switch, key [3] will be OFF by default. If the keypad has an anti-tamper switch, key [3] will be ON by default.
How Do I Configure The Keypad?
1) Press
[
ENTER
]
2) Enter your
[
INSTALLER
CODE
]
(default: 0000 / 000000)
3) Press the
[
PG
]
(1686H/V) /
[
FNC
1]
(1689) key and hold it for 3 seconds.
4) Press the desired key (
[1]
to
[3]
. See below)
5) Press
[
ENTER
]
to exit programming mode
To access the Data Display Mode, press the
[
ENTER
]
key after entering a section and before entering any data. The
three LEDs as indicated below will begin to flash indicating that you are in the Data Display Mode.
Each time the
[
ENTER
]
key is pressed, the keypad will display the next digit in the current section and will continue
through all the following sections one digit at a time without changing the programmed values. Not available for
sections using the Multiple Feature Select Method. Press the
[
CLEAR
]
key at any time to exit the Data Display Mode.
Содержание 1759MG