Spectra 1759MG
- 19 -
Programming Guide
Reprogram All Modules
Paradox Memory Key (PMC-3)
Download to DESTINATION Control Panel
1) Remove AC and battery power from the control panel.
2) Insert the Memory Key onto the serial connector labelled
KEY
on the Spectra control panel to
which you wish to download the contents of the memory key to.
3) Re-apply AC and battery power.
4) Enter installer programming mode, enter section
[900]
, then press
[
ENTER
]
to acknowledge.
5) When the keypad emits a “confirmation beep”, remove the Memory Key.
6) Enter section
[750]
to reprogram the modules with the information downloaded from the
Paradox Memory Key.
Copy to Memory Key from SOURCE Control Panel
1) Remove AC and battery power from the control panel.
2) Insert Memory Key onto the serial connector labelled
KEY
on the Spectra control panel that
you want to copy. Make sure the write protect jumper of the Memory Key is on.
3) Re-apply AC and battery power.
4) Enter installer programming mode, enter section
[902]
, then press
[
ENTER
]
to acknowledge.
5) When the keypad emits a Confirmation Beep, remove the Memory Key. Remove the
Memory Key’s jumper if you do not wish to accidentally overwrite its contents
.
[
750
]
After removing an expansion module from the communication bus, the control panel keeps the module’s
programmed sections in memory. Therefore, if you add or replace a module you can re-program the module with the
settings saved in the control panel. To do so, enter section
[750]
and press
[
ENTER
]
. The keypads will beep twice
every second until the procedure is completed.
[
900
]
DOWNLOAD
FROM
PARADOX
MEMORY
KEY
TO
DESTINATION
CONTROL
PANEL
.
[
902
]
COPY
TO
MEMORY
KEY
FROM
SOURCE
CONTROL
PANEL
.
Jumper ON =
Read from and/or write to
memory key
Paradox
Memory Key
PMC-3
Jumper OFF =
Write protected (read
from memory key only)
Insert Paradox Memory Key
onto the
‘MEMORY KEY’
connector.
Partial view of Spectra
1759MG control panel
Содержание 1759MG
Страница 2: ......