Spectra 1759MG
- 22 -
Programming Guide
Bold
= Default Setting
PGM Programming
The PGM Deactivation event can be used as another activation event if the PGM Timer (section
[554]
) is programmed with a
value other than 000. The APR3-PRT1 module uses the same PGM events as the Spectra control panel, please refer to
Section #
Decimal Value (000-255)
Description
Default Value
[554]
___/___/___ seconds (000 = follow deactivation event)
PGM1
TIMER
5s
Section #
Event Group # Sub-Group #
Partition #
[555]
PGM1 Activation Event
___/___
___/___
___/___
[556]
PGM1 Deactivation Event
___/___
___/___
___/___
Clock Programming
For example, to enter the date March 26, 2004 you would enter 2004 (year), 03 (month), and 26 (day).
Section #
Value
[557]
Year ___/___/___/___ Month ___/___ Day ___/___
Section [553]: Serial and Parallel Port Setup Options
Option
OFF
ON
[1]
Serial port
N
Disabled
N
Enabled
[2]&[3]
N
see table
N
see table
N
see table
N
see table
[4]
Parallel port
N
Disabled
N
Enabled
[5]
Off-line status ignored (parallel port only)
N
Disabled
N
Enabled
[6]
Paper empty status ignored (parallel port only)
N
Disabled
N
Enabled
[7]
Printer fault status ignored (parallel port only)
N
Disabled
N
Enabled
[8]
Printer busy status ignored (parallel port only)
N
Disabled
N
Enabled
Baud Rate Settings
[2]
[3]
APR-PRT1
APR3-PRT1
OFF
OFF
1200 baud
(default)
2400 baud
(default)
ON
OFF
2400 baud
9600 baud
OFF
ON
9600 baud
19200 baud
ON
ON
19200 baud
57600 baud