Spectra 1759MG
- 30 -
Programming Guide
Appendix A - Ademco CID Report Code List (Prog.)
If using the Ademco Contact ID Programmable code format, enter the 2-digit hexadecimal value from the table below (Prog.
Value) into sections
[160]
to
[213]
to program the desired report codes.
To enter a 0 value press the [
FORCE
] key.
CID#
Reporting
Prog.
Code
Value
CID#
Reporting
Prog.
Code
Value
CID#
Reporting
Prog.
Code
Value
MEDICAL ALARMS - 100
203
Gate Valve Sensor
2E
401
O/C by User
5B
100
Medical Alarm
01
204
Low Water Level
2F
402
Group O/C
5C
101
Pendant Transmitter
02
205
Pump Activated
30
403
Automatic O/C
5D
102
Fail to Report In
03
206
Pump Failure
31
404
Late to O/C
5E
FIRE ALARMS - 110
SYSTEM TROUBLES - 300 & 310
405
Deferred
5F
110
Fire Alarm
04
300
System Trouble
32
406
Cancel
60
111
Smoke
05
301
AC Loss
33
407
Remote Arm/Disarm
61
112
Combustion
06
302
Low System Battery
34
408
Quick Arm
62
113
Water Flow
07
303
RAM Checksum Bad
35
409
Keyswitch O/C
63
114
Heat
08
304
ROM Checksum Bad
36
REMOTE ACCESS - 410
115
Pull Station
09
305
System Reset
37
411
Callback Request Made
64
116
Duct
0A
306
Panel Program Changed
38
412
Success - Download Access
65
117
Flame
0B
307
Self-Test Failure
39
413
Unsuccessful Access
66
118
Near Alarm
0C
308
System Shutdown
3A
414
System Shutdown
67
PANIC ALARMS - 120
309
Battery Test Failure
3B
415
Dialer Shutdown
68
120
Panic Alarm
0D
310
Ground Fault
3C
ACCESS CONTROL - 420
121
Duress
0E
SOUNDER/RELAY TROUBLES - 320
421
Access Denied
69
122
Silent
0F
320
Sounder Relay
3D
422
Access Report By User
6A
123
Audible
10
321
Bell 1
3E
SOUNDER RELAY DISABLES - 520
BURGLAR ALARMS - 130
322
Bell 2
3F
520
Sounder/Relay Disabled
6B
130
Burglary
11
323
Alarm Relay
40
521
Bell 1 Disable
6C
131
Perimeter
12
324
Trouble Relay
41
522
Bell 2 Disable
6D
132
Interior
13
325
Reversing
42
523
Alarm Relay Disable
6E
133
24-Hour
14
SYSTEM PERIPHERAL TROUBLES - 330 & 340
524
Trouble Relay Disable
6F
134
Entry/Exit
15
330
System Peripheral
43
525
Reversing Relay Disable
70
135
Day/Night
16
331
Polling Loop Open
44
COMMUNICATION DISABLES - 550 & 560
136
Outdoor
17
332
Polling Loop Short
45
551
Dialer Disabled
71
137
Tamper
18
333
Exp. Module Failure
46
552
Radio xmitter Disabled
72
138
Near Alarm
19
334
Repeater Failure
47
BYPASSES - 570
GENERAL ALARMS - 140
335
Local Printer Paper Out
48
570
Zone Bypass
73
140
General Alarm
1A
336
Local Printer Failure
49
571
Fire Bypass
74
141
Polling Loop Open
1B
COMMUNICATION TROUBLES - 350 & 360
572
24-Hour Zone Bypass
75
142
Polling Loop Short
1C
350
Communication
4A
573
Burg. Bypass
76
143
Expansion Module Failure
1D
351
Telco Fault 1
4B
574
Group Bypass
77
144
Sensor Tamper
1E
352
Telco Fault 2
4C
TEST/MISC. - 600
145
Expansion Module Tamper
1F
353
Long Range Radio
4D
601
Manual Trigger Test
78
24-HOUR NON-BURGLARY - 150 & 160
354
Fail to Communicate
4E
602
Periodic Test Report
79
150
24-Hour Non-Burglary
20
355
Loss of Radio Supervision
4F
603
Periodic RF Xmission
7A
151
Gas Detected
21
356
Loss of Central Polling
50
604
Fire Test
7B
152
Refrigeration
22
PROTECTION LOOP TROUBLES - 370
605
Status Report to Follow
7C
153
Loss of Heat
23
370
Protection Loop
51
606
Listen-in to Follow
7D
154
Water Leakage
24
371
Protection Loop Open
52
607
Walk Test Mode
7E
155
Foil Break
25
372
Protection Loop short
53
621
Event Log Reset
7F
156
Day Trouble
26
373
Fire Trouble
54
622
Event Log 50% Full
80
157
Low Bottled Gas Level
27
SENSOR TROUBLES - 380
623
Event Log 90% Full
81
158
High Temp
28
380
Sensor Trouble
55
624
Event Log Overflow
82
159
Low Temp
29
381
Loss of Super. -RF
56
625
Time/Date Reset
83
161
Loss of Air Flow
2A
382
Loss of Super. - RPM
57
626
Time/Date Inaccurate
84
FIRE SUPERVISORY - 200 & 210
383
Sensor Tamper
58
627
Program Mode Entry
85
200
Fire Supervisory
2B
384
RF xmtr. Low Battery
59
628
Program Mode Exit
86
201
Low Water Pressure
2C
OPEN/CLOSE - 400
631
Exception Schedule Change
87
202
Low CO2
2D
400
Open/Close
5A
654
System Inactivity
88