Spectra 1759MG
- 13 -
Programming Guide
Bold
= Default Setting
* This option cannot be done using a keyswitch. Force arming is not supported by keyswitches.
Section [130]: Arming/Disarming Options
Option
OFF
ON
[1]
One-touch Regular Arming
N
Disabled
N
Enabled
[2]
One-touch Stay Arming
N
Disabled
N
Enabled
[3]
One-touch Force Arming
N
Disabled
N
Enabled
[4]
One-touch bypass programming
N
Disabled
N
Enabled
[5]
Restrict arming on battery failure
N
Disabled
N
Enabled
[6]
Restrict arming on Tamper failure
N
Disabled
N
Enabled
[7]
Bell Squawk on Arm/Disarm with keypad
N
Disabled
N
Enabled
[8]
Beep on exit delay
N
Disabled
N
Enabled
Section [131]: Arming/Disarming Options
Option
OFF
ON
[1]
Report Disarming
N
Always
N
Only after alarm
[2]
Regular Arming switches to Force Arming *
N
Disabled
N
Enabled
[3]
Bell Squawk on Arm/Disarm with remote control
(must be enabled for UL installations)
N
Disabled
N
Enabled
[4]
No exit delay when Arming with a remote control
N
Disabled
N
Enabled
[5]
No exit delay beeps and no Bell Squawk when
Stay Arming
N
Disabled
N
Enabled
[6]
Restrict arming on wireless transmitter
supervision loss
N
Disabled
N
Enabled
[7]
Generate supervision loss if detected on
bypassed wireless zone
N
Yes
N
No
[8]
Future Use
N
N/A
N
N/A
Section [132]: Zone Options
Option
OFF
ON
[1]&[2]
N
see table
N
see table
N
see table
N
see table
[3]
Generate tamper if detected on bypassed zone
N
Yes
N
No
[4]
EOL (end-of-line) resistors
N
No EOL
N
Use EOL Resistors
[5]
Future use
N
N/A
N
N/A
[6]
Report zone restore
N
On Bell Cut-off
N
On Zone Closure
[7]&[8]
N
see table
N
see table
N
see table
N
see table
Tamper
Recognition
Options
[1]
[2]
OFF
OFF
Disabled
(default)
OFF
ON
When disarmed:
GENERATES
TROUBLE
ONLY
When armed: Follows
Zone Alarm Types
ON
OFF
When disarmed:
GENERATES
SILENT
ALARM
When armed: Follows
Zone Alarm Types
ON
ON
When disarmed:
GENERATES
AUDIBLE
ALARM
When armed: Follows
Zone Alarm Types
Wireless
Transmitter Supervision
Options
[7]
[8]
OFF
OFF
Disabled
(default)
OFF
ON
When disarmed:
GENERATES
TROUBLE
ONLY
When armed: Follows
Zone Alarm Types
ON
OFF
When disarmed:
GENERATES
SILENT
ALARM
When armed: Follows
Zone Alarm Types
ON
ON
When disarmed:
GENERATES
AUDIBLE
ALARM
When armed: Follows
Zone Alarm Types
Содержание 1759MG
Страница 2: ......